7.4.2
Re-zeroing with HART® communicator
See section 6.2.4.10.
7.5
Fault finding
The internal microprocessor performs continuous self-testing of optical and electronic functions.
If a fatal error should occur in the electronics or optics, the processor will generate a 0mA output
signal, indicating detector failure. The detector should then be checked according to flow chart
on the left. Do not return the instrument to the supplier for repair if this test has not been performed.
If the IR transmission in the optical path is attenuated to 50-70% of its original value, the output
signal will go down to Early Dirty Optics (see section 6.1 for further details).
If the IR transmission is further attenuated, the output signal will go down to Dirty Optics (fault). In
this condition the detector will not detect gas (see section 6.1 for further details).
If the optics are contaminated, wipe them with a clean cloth and mild detergent according to
instructions in section. 7.1. The optics must be cleaned even if they appear not to be contaminated.
A signal output equal to 0 mA can be due to a power supply failure. Check first that voltage
supply at detector terminal is between 18VDC and 32VDC.
Avoid direct light on lens and mirror if testing without the Weather Protection.
Ensure that no gas is present in the measuring chamber when testing.
A temperature fault is output if ambient temperature is outside -85°C/+85°C.
Summary of Contents for Everywhereyoulook GD10-P00
Page 1: ...850 811250 Revision 13b GD10 P00 and GD10 PE0 INFRARED POINT GAS DETECTOR OPERATING MANUAL...
Page 10: ...GD10 P00 and GD10 PE0 INFRARED POINT GAS DETECTOR OPERATING MANUAL 4 850 811250 Revision 13b...
Page 14: ...GD10 P00 and GD10 PE0 INFRARED POINT GAS DETECTOR OPERATING MANUAL 8 850 811250 Revision 13b...
Page 18: ...GD10 P00 and GD10 PE0 INFRARED POINT GAS DETECTOR OPERATING MANUAL 12 850 811250 Revision 13b...
Page 46: ...GD10 P00 and GD10 PE0 INFRARED POINT GAS DETECTOR OPERATING MANUAL 40 850 811250 Revision 13b...
Page 47: ...GD10P00 and GD10PE INFRARED POINT GAS DETECTOR OPERATING MANUAL 850 811250 Revision 13b 41...
Page 48: ...GD10 P00 and GD10 PE0 INFRARED POINT GAS DETECTOR OPERATING MANUAL 42 850 811250 Revision 13b...
Page 52: ...GD10 P00 and GD10 PE0 INFRARED POINT GAS DETECTOR OPERATING MANUAL 46 850 811250 Revision 13b...
Page 56: ...GD10 P00 and GD10 PE0 INFRARED POINT GAS DETECTOR OPERATING MANUAL 50 850 811250 Revision 13b...
Page 57: ...GD10P00 and GD10PE INFRARED POINT GAS DETECTOR OPERATING MANUAL 850 811250 Revision 13b 51...
Page 58: ...GD10 P00 and GD10 PE0 INFRARED POINT GAS DETECTOR OPERATING MANUAL 52 850 811250 Revision 13b...
Page 59: ...GD10P00 and GD10PE INFRARED POINT GAS DETECTOR OPERATING MANUAL 850 811250 Revision 13b 53...