1. 

INTRODUCTION, CAUTIONS, AND SPECIFICATIONS 

The Teledyne API Opti-Sense 5200 is a state-of-the-art Non Dispersive InfraRed (NDIR)-

based sensor that is designed to monitor SIF4 (Silicon Tetrafluoride) concentration, 

typically at sub-atmospheric  pressure. 
The OPTI-Sense unit is designed to be mounted vertically. Horizontal mounting is also 

acceptable. Two KF16 fittings are provided to effectuate the pneumatic connections. 

Electrical connections are on the rear panel of the instrument. Power and control signals 

are applied through the DB15 connector. The RS-232 connector should be connected to a 

laptop computer if the graphical user interface (GUI) will be used. 
The OPTI-Sense 5200 can be used qualitatively three minutes after power up. For accurate 

quantitative results, allow the unit to warm up for thirty minutes. The OPTI-Sense should 

be allowed to warm up overnight for applications in which low drift is critical. Purge and 

zero the instrument after the warm-up period is completed. 

 

CAUTIONS 

Please review these instructions carefully to ensure proper installation, operation and care 

of the system to minimize the risk of personal injury or product damage due to improper 

handling. 
 

 

HAZARD: Toxic, Corrosive Gas 

  SIF4 (Silicon Tetrafluoride) is a toxic, corrosive, nonflammable 

gas packaged at pressure up to 1000 psig. It has a sharp 

suffocating odor. The gas is colorless but fumes white in moist 

air. Hydrolyzes to very corrosive hydrofluoric acid on contact 

with moisture. Can cause severe chemical burns if inhaled or 

upon skin contact. When entering released area, wear self-

contained breathing apparatus (SCBA). Fully protective suits 

are required in large releases. 

  Install appropriate safety monitoring equipment wherever SIF4 

is used. 

  Materials in contact with SIF4 should be suitable for such use.  

316L Stainless, Barium Fluoride (BaF2), Teflon™, Chemraz™ 

are recommended. 

 

WARNING: Electrical Shock Hazard 

When performing any maintenance to the unit, make sure all DC 

power is disconnected from the unit 

 

CAUTION: Risk of Damage to Instrument 

Use only TAPI-recommended spare parts. Substitution parts could 

result in damage to the equipment, may create hazardous 

conditions, and will void the warranty. 

 

Summary of Contents for OPTI-Sense 5200

Page 1: ...r TELEDYNE API TAPI 9970 CARROLL CANYON ROAD SAN DIEGO CALIFORNIA 92131 1106 USA Toll free Phone 1 800 324 5190 Phone 1 858 657 9800 Fax 1 858 657 9816 Email api sales teledyne com Website http www te...

Page 2: ......

Page 3: ...OF COPYRIGHT 2022 Teledyne API TAPI All rights reserved TRADEMARKS All trademarks registered trademarks brand names or product names appearing in this document are the property of their respective own...

Page 4: ...ion or proper tools could result in damage to the part s and or the instrument Technician Symbol All operations marked with this symbol are to be performed by qualified maintenance personnel only Elec...

Page 5: ...gnements sp cifiques MISE EN GARDE Surface chaude Ne pas toucher Toucher certaines parties de l instrument sans protection ou sans les outils appropri s pourrait entra ner des dommages aux pi ces ou l...

Page 6: ...vided but not manufactured by TAPI is warranted and will be repaired to the extent and according to the current terms and conditions of the respective equipment manufacturer s warranty PRODUCT RETURN...

Page 7: ...the careful and effective use of the instrument and related pertinent information ATTENTION COULD DAMAGE INSTRUMENT AND VOID WARRANTY This special notice provides information to avoid damage to your i...

Page 8: ...L INSTALLATION 9 3 ELECTRICAL CONNECTIONS 11 RS 232 Connector 11 I O Connector 11 Fault DO Specifications 12 Over Voltage Protection 12 4 SYSTEM OPERATION 13 Zeroing the OPTI Sense 13 5 INSTRUMENT ERR...

Page 9: ...iod is completed CAUTIONS Please review these instructions carefully to ensure proper installation operation and care of the system to minimize the risk of personal injury or product damage due to imp...

Page 10: ...second Analog scaling Filter type 1 10 VDC corresponds to 0 0 0 2 units of absorbance 10Watts factory set Leak Testing Vacuum Leak Tight Cell Gas Connection KF16 300 Series stainless steel Pressure Ra...

Page 11: ...ENTION Ensure adequate space to access connectors and to remove cover when necessary for servicing Ensure adequate clearance to allow free air flow for cooling and to avoid high heat generating equipm...

Page 12: ...is also acceptable Figure 2 2 Inlet right and Outlet left Connectors The flow of gas through the unit should be interrupted when there is a possibility of particulate matter soiling the windows or lo...

Page 13: ...nnected to the COM1 port of the computer running the GUI software I O CONNECTOR Table 3 1 below shows the I O connector pinout Table 3 1 I O Connector Pinout Pin Connection Notes 1 N C 2 Analog Signal...

Page 14: ...automatically when they no longer affect instrument data For example the three minute instrument warm up period is indicated as an error to allow detection of accidental power disruption the Fault DO...

Page 15: ...ow the line must be held low for at least 200 ms Operating Voltage HIGH 24VDC 10 Operating Voltage LOW 0VDC Nominal 4VDC Max Zeroing will take approximately five seconds during normal operation Zeroin...

Page 16: ...r contamination indicates presence of particulate matter or a deposited film Make sure that provisions are in place to prevent particulate matter or film deposition onto the surfaces of the absorption...

Page 17: ...chnical Support department for any technical assistance needed Teledyne API Technical Support 9970 Carroll Canyon Road San Diego California 92131 1106 USA Toll free Phone 1 800 324 5190 Phone 1 858 65...

Reviews: