Page 1: ...Installation Operation Manual FCC ID LWNF21 E1 F21 E1 type Industrial Radio Remote Controller TELECRANE Lee s Hi tech Ent Co Ltd 6 14 2002 ...

Page 2: ...le Of Contents Part 1 Operator s Manual Chapter 1 Warranty Chapter 2 Precautions Of Operation Chapter 3 F21 E1 Standard Accessories Chapter 4 Operation Chapter 5 Troubleshooting and Software Installation 1 ...

Page 3: ...fer to instruction manual for additional information High Voltage Indicates presence of hazardous voltage Unsafe practice Could result in severe personal injury Protective Earth Ground Indicates protective earth terminal Warning Denotes a hazard Included text gives proper procedures Failure to follow instructions could result in severe personal injury and or property damage Caution Denotes a hazar...

Page 4: ...duct must be returned to a service facility designated by TELECRANE Buyer will pay shipping charges to TELECRANE while TELECRANE will pay return shipping charges 1 3Excluded Items This warranty does not include consumptive parts such as batteries fuses buttons relays Also this warranty does not cover defects caused by improper installation improper or insufficient maintenance unauthorized modifica...

Page 5: ...smitter should be placed in a safe area when not in use to avoid accidental pressing of buttons The crane should be equipped with main power relay limit switch and other safety devices The GND ground of the receiver must be in contact with the metal part of the crane or electrical shock may occur Don t use equipment during lightening or high electrical interference conditions Make sure that the ba...

Page 6: ...transmitter will send out EMS signal first to de energize all of motion relays inside the receiver to stop crane s moving Notice the motions which are set as Bypass EMS will continuously move and then the LED indicator on transmitter will light continuously At this time need to be replaced with AA size alkaline batteries All batteries should be replaced at the same time Don t use manganese zinc ba...

Page 7: ...erence In the event of sensing an emergency situation the F21 will perform an emergency stop of the equipment It is important to properly install the F21 system so it can perform the emergency shutdown properly In case of an Emergency please follow the steps below and ask the distributor for service immediately 1 Press EMS button 2 Turn the rotary key switch to OFF position and remove it 3 Switch ...

Page 8: ...ies When you get a standard and full set of F21 E1 system it includes the following item 2 Receiver one unit 1 Transmitter one unit Remarks 1 Hamming Distance 4 2 I D Code More than 42 billion ID Code 32bit 3 Channel Spacing 267 5KHz 7 ...

Page 9: ... 4 Operation 4 1 F21 E1 Transmitter s parts LED indicator Pushbuttons Emergency stop Rotary key Remarks 1 Power Two 1 5Volt Alkaline Batteries AA Size 2 Dimensions 156 61 51mm 3 Weight about 320g W batteries 8 ...

Page 10: ...iver s parts Antenna Diagram of control contact with LED indicator Output cable Remarks 1 Input Voltage 110VAC 50 60Hz 10 2 Output Relays 10A 250VAC 3 Dimensions 185 85 85mm L W H 4 Weight about 550g W O wire cable 9 ...

Page 11: ...hen a pushbutton is programmed as a TOGGLE or an ON OFF function with bypass EMS control it won t work correctly with the standard wire setting diagram In order to program a pushbutton as TOGGLE or ON OFF with bypass EMS control the MAIN wire and COM wire must be swapped 4 4 2 Changing the frequency It is very simple to change the frequency of the new F21 crystal series The systems frequency can b...

Page 12: ...ote Setting Remote setting allows you to pair the new TX and RX if one of them is damaged In order to work the TX RX must have the same ID codes and frequency Using remote setting will make both the TX and RX to have the same ID codes Prior to remote setting please follow the instruction below a Make sure both TX and RX are of the same model and frequency b In order to avoid any interference place...

Page 13: ...4 4 7 Wire Diagram 12 ...

Page 14: ...repair 2 TX LED flashes slowly every 0 5 sec The memory of the TX is defective Contact the distributor for repair 3 RX Main LED flashes slowly every 0 5 sec but the relays are not operating at all The RX memory is defective Please contact the distributor for repair 4 The TX LED flashes every 2 seconds when the battery is low Please replace the new battery immediately 5 2 Simple Troubleshooting 1 T...

Page 15: ...he instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following meas...