Energy 2510 D
Rev. 004
10
GB
Place the muffler (fig. 14 ref. 8) under the floor of
the vehicle via 2 suspending rubber stoppers
code 02440 (fig. 14 ref. 9 and 10)
4.4 Connecting the fuel pipes
No. 2 pipes come out of the generator. The pipe
with a larger inside diameter (7mm), on which the
fuel oil filter is located, is the fuel inlet one. The
pipe with a smaller inside diameter (5mm) is the
fuel return one.
If an independent tank is fitted, the installation
position must be chosen so as ensure that the
fuel pipe length is reduced to a minimum. Also
ensure that the hose cross-section is not reduced
due to choking, bending or crushing.
We advise to install the tank at the same height
as the generating set. If it is fitted in a lower
position, the installation height difference should
never exceed 20 cm.
Do not install the fuel tank next to sources of
heat; the tank should be protected from the risk
of outside water seeping.
Carry out the fuel tank-to-generating set
connection by using rubber hoses
suitable for
Diesel oil, with an ID of 7 mm (code 00536) for
the fuel delivery pipe and an ID of 5 mm (code
01548) for the return pipe.
Both fuel pick-up and
return must take place in the tank and NOT
through branch pipes.
Should the fuel flow rate to the generator be
insufficient owing to a long route covered by the
feeding pipe, it is advisable to install an additional
fuel pump code 00507. This pump, which is
equal to the one fitted inside the generating set,
is electrically operated. The electric control which
drives the additional pump is located in a 3 pin
connector (fig. 15 ref. 1) in the generating set
near the 12 Vdc terminals.
4.5 Connecting the Fuel Reserve
If the tank is provided with a fuel reserve
indicator. To electrically connect this component,
the reserve wire on the fuel tank must be
connected, via an electric lead, to the 3-pin
connector terminal (fig. 15 ref. 2) inside the
generating set, close to the 12 Vdc terminals. If
the tank reserve indicator has 2 leads, connect
the other lead to the ground.
A special fuel warning light located on the control
panel (fig. 24. ref. 8) will light up to show that the
fuel level inside the tank has gone below the safe
reserve level.
4.6 Auxiliary battery charger connection
It is possible to connect a battery other than the
one connected to the generator through the 2-pin
connector (fig. 15 ref. 3), on which there is an
alternated voltage of 12 V 50 Hz, max current 5
A; this can be done by installing a charge
regulator RCB (optional, item code 05424)
between this connector and the battery.
Do not directly connect
any battery to this connector!
5 Electric connections
5.1 Preparing the Wiring connection
By using the special key to open the lock,
remove the front door (fig. 16 ref. 3).
Then remove the bottom surface locking screw
(fig. 16 ref. 1) on both sides.
Summary of Contents for Telair ENERGY 2510D
Page 23: ...Rev 004 Energy 2510 D GB 23 12 ENERGY 2510 D WIRING DIAGRAM...
Page 24: ...Energy 2510 D Rev 004 24 GB 13 ENERGY 2510 D LIST OF SPARE PARTS...
Page 25: ...Rev 004 Energy 2510 D GB 25...
Page 26: ...Energy 2510 D Rev 004 26 GB...
Page 27: ...Rev 004 Energy 2510 D GB 27...
Page 28: ...Energy 2510 D Rev 004 28 GB...
Page 42: ...Energy 2510 D Rev 004 42 GB...
Page 43: ...Rev 004 Energy 2510 D GB 43...
Page 44: ......