Installation instructions
│
R2
│
Annex A: Implementation Specifications – Lynx (in
English)
ANNEX A: IMPLEMENTATION SPECIFICATIONS –
LYNX (IN ENGLISH)
A.1 M odbu s C ommands
Function
Sub-function
Function name
3
0x03
Read Holding Registers
4
0x04
Read Input Registers
(Equivalent to Read Holding Registers)
16
0x10
Write Multiple Registers
17
0x11
Report Slave ID
22
0x16
Mask write Register
65
0x41
Tele Radio – Event management
0x01
– Poll Events
0x02
– Delete Events
0x03
– Respond to Event
66
0x42
Tele Radio – Transmitter management
0x01
– Get total number of transmitters
0x02
– Get transmitter Ids
0x03
– Delete all transmitters
0x04
– Add one transmitter by ID
0x05
– Enter Learn mode
67
0x43
Tele Radio – Interrupt (Not implemented)
0x01
– Change interrupt
A.2 Register M ap
Changes to registers will be applied directly after a Modbus response has been sent
from the slave. I.e. if new serial setting is written to 0x0001 by the master, the slave
(Lynx) will change to the new serial setting directly after it has sent its response.
Address
Contents
0x0000
Status register
0x0001
Reserved
0x0002
Reserved
0x0003
RS232 Modbus address (default 0x66 )