background image

Teldat Connect-KFPlus

Installation Manual

Copyright© TeldatDm1001-I Version 1.2 02/2020 Teldat S.A.

Teldat S.A.

Manual

Teldat Connect-KFPlus

1

Summary of Contents for Connect-KFPlus

Page 1: ...Teldat Connect KFPlus Installation Manual Copyright TeldatDm1001 I Version 1 2 02 2020 Teldat S A Teldat S A Manual Teldat Connect KFPlus 1...

Page 2: ...S A offers no warranty whatsoever for information contained in this manual Teldat S A is not liable for any direct indirect collateral consequential or any other damage connected to the deliv ery supp...

Page 3: ...4 Chapter 3 Components and Power Supply 5 3 1 Components 5 3 1 1 Front Panel 5 3 1 2 Rear Panel 7 3 1 3 Side Panels 9 3 1 4 Underside Panel 10 3 2 Mounting an Anti Theft Security Cable 10 3 3 Rack ins...

Page 4: ...20 4 12 Intended use of the equipment 20 Appendix A Technical Information 21 A 1 Troubleshooting 21 A 2 Updating the software 21 A 3 Connecting to the device 21 A 3 1 Connecting using the local conso...

Page 5: ...ess LAN Interface Radio 2 27 A 5 9 Configuration Interface 27 A 5 10 Power Supply 27 A 5 11 Dimensions and weight 28 A 5 12 Environmental Specifications 28 Appendix B CE Radio Information 29 B 1 WI FI...

Page 6: ...I Related Documents Teldat Dm704 I Configuration and Monitoring Teldat Dm748 I Software Updating bintec Next Generation WLAN Manual Teldat S A Related Documents Teldat Connect KFPlus 1...

Page 7: ...ble features in the Teldat Connect KFPlus router Technical specifications Power supply requirements Elements that can be connected when the router is operating How to install and uninstall the modules...

Page 8: ...software can be upgraded on a regular basis for maintenance purposes and when new features are developed Contact information Web http www teldat com Email support teldat com Tel 34 918 076 565 Fax 34...

Page 9: ...n on the state of the device and reference the condition of the hardware components indic ating whether or not there is connectivity data flow etc For further information on the LED panel please see C...

Page 10: ...llows FRONT PANEL ELEMENTS Item Description A LED panel The LED panel provides information on the status of the components indicating whether they are active or not and on network activity LEDs LED De...

Page 11: ...g on the model Access Point 2 4 GHz radio Off Radio module and or SSIDs inactive Red No connection or disabled shutdown Amber Enabled but no associated STAs Green Connected Blinking connection data ac...

Page 12: ...e refer to 4 port Ethernet switch Connections on page 14 LAN Connector Switch on page 22 LAN Interface on page 24 D Eth WAN 1 Base T WAN Gigabit Ethernet For more information about the WAN interface r...

Page 13: ...are not used on this router J On Off switch K Power source connection PSU Refer to Power Source on page 11 for more information about Power connection and Power Supply on page 27 for power specificati...

Page 14: ...ure shows the router s WAN LED indicators only for the Base T connector Fig 4 WAN LEDs WAN LED indicators LED Description Yellow Connected to 10 M Steady Not transferring data Blinking Transferring da...

Page 15: ...sive rubber feet these are not required for rack mounting 3 2 Mounting an Anti Theft Security Cable Teldat Connect KFPlus devices have been equipped with a standard Kensington security slot to which a...

Page 16: ...eldat Connect KFPlus devices can be placed as standalone on a flat stable surface The adhesive rubber feet must be stuck to the underside panel to prevent the router from sliding Make sure there is en...

Page 17: ...the same grounded power out let 3 5 1 1 Connecting Make sure the on off power supply switch is in the OFF position 0 Make sure the power supply is NOT connected to the mains or to the device Connect...

Page 18: ...his configuration will provide two Wi Fi networks test_ssid_1 and test_ssid_2 The first one is placed in the 2 4 GHz band and the second one in the 5 GHz band The password for both networks matches th...

Page 19: ...100 1000 Base T link but they cannot work simultaneously These interfaces are totally independent from the switch and are handled as every other interface Please pay careful attention to the labeling...

Page 20: ...KFPlus has an SMA connector in the rear panel that is not used on this router 3 7 5 Wireless LAN internal antennas The Teldat Connect KFPlus has two integrated antennas for an internal Wireless LAN m...

Page 21: ...de Madrid 28760 Tres Cantos Madrid Spain International Phone 34 91 807 65 65 4 2 Risk identification WARNING Signal word used to designate a potentially dangerous situation that may cause severe inju...

Page 22: ...ida previstos y que su tratamiento debe estar separado del de los residuos urbanos 4 5 REACH In compliance with the REACH Candidate List the delivered product and product packaging do not contain chem...

Page 23: ...aipei County 23145 TW Input Voltage 100 240 Vac Input AC frequency 50 60 Hz Output voltage 12 0 V Output current 3 34 A Output power 40 0 W Average active efficiency 88 8 Efficiency at low load 10 84...

Page 24: ...y 2015 863 UE RoHS del Parlamento Europeo y del Consejo The EC declaration of conformity and additional product documentation can be accessed here http www teldat com conformity 4 9 CE Marking This e...

Page 25: ...ipment operates see appendix WI FI specifications on page 29 4 12 Intended use of the equipment The Teldat Connect KFPlus device can be deployed as a Customer Premises Equipment CPE in enterprise bran...

Page 26: ...ailable for use A 2 Updating the software The Teldat Connect KFPlus router can be updated to new versions Please contact your dealer for further details on new releases There are several ways to updat...

Page 27: ...plied with the device and an RJ45 female DB9 female adapter also provided Fig 15 Connecting for Configuration For further information please see manual Teldat Dm704 I Configuration and Monitoring A 4...

Page 28: ...tandard SFP connector A 4 4 WWAN Connector Devices equipped with this interface have up to four SMA female connectors installed SMA Female PIN ANT Internal External RF in out GND A 4 5 GPS Connector D...

Page 29: ...l NEGATIVE A 5 Technical Specifications A 5 1 Hardware Architecture PROCESSORS Freescale QorIQ MEMORY 256 MBytes in SDRAM STORAGE UNIT FLASH Memory 32 MBytes A 5 2 LAN Interface PROTOCOLS Ethernet 802...

Page 30: ...ode 1550 nm CONNECTOR Standard SFP connector A 5 5 Wireless WAN interface WWAN Standard Bands Not used by the router CONNECTOR Five SMA connectors not used by the router SIM Slots 2 Mini SIM 2FF not u...

Page 31: ...idth MCS0 15 allow up to 150 Mbps PHY rate at 20 MHz channel bandwidth 2 streams short guard interval Up to 173 3 Mbps QAM 256 with clients that support QAM 256 802 11n 40 MHz channel bandwidth MCS0 1...

Page 32: ...2 streams short guard interval 802 11ac 20 MHz channel bandwidth Allow up to 173 Mbps PHY rate with two streams or up to 87 Mbps PHY with one stream 802 11ac 40 MHz channel bandwidth Allow up to 400 M...

Page 33: ...1 U high Rack mount enclosure L x W x H 310 x 197 x 45 mm WEIGHT 2 04 Kg A 5 12 Environmental Specifications TEMPERATURE OPERATING NORMALLY 0 C to 45 C STORED 25 C to 70 C RELATIVE HUMIDITY 5 to 90 Te...

Page 34: ...N 802 11a b g n ac Frequency Range 802 11b g n HT20 2412 2472MHz 802 11n HT40 2422 2462MHz 802 11a n HT20 ac VHT20 5180 5240 MHz 5260 5320 MHz 5500 5700 MHz 802 11n HT40 ac VHT40 5190 5230 MHz 5270 53...