elmeg DECT200 Multicell System
bintec elmeg
Configuring the system on the DECT Manager
¤
If you wish to remove the base station from the network, click on
Delete base station
.
If you delete the base station, all data for this base station will be deleted from the DECT
Manager.
¤
Click on
Set
to apply the changes on this page.
Synchronising base stations
Synchronisation and the logical structuring of the base stations in clusters are prerequisites for
the functioning of the PABX, the radio connection between base stations and mobile phones
and the handover.
To carry out the synchronisation you will need the plan of the clusters with the synchronisation
level for each base station.
¤
View the list of installed base stations and check that all base stations have been registered
and configured (
). They will then appear in the list in the following window:
Settings
¢
Network and connectors
¢
Base station synchronisation
¤
Now assign the cluster number and synchronisation level to each base station as given in the
plan.
¤
Select
Set
.
Synchronisation starts automatically and contact with handsets that have already been
registered is interrupted.
Workshop West
Stairwell
Workshop Central
Workshop East
Admin First Floor
Admin Second Floor
Admin Ground Floor