background image

RDSI_B
RDSI_B
SECURITY ENGINE
PCI device: Host bridge

(Bus: 0, Device: 0, Function: 0)
(Subs. Vendor: 0x0000, Subs. Device: 0x0000)

Slot 1 - PCI device: CardBus bridge

(Bus: 0, Device: 10, Function: 0)
(Subs. Vendor: 0x0000, Subs. Device: 0x0000)

Current production date: 00 00
Current software license: 12 15
Current serial number: 550/05646
BIOS MAC Add: 00-a0-26-a0-16-0e

Teldat S.A.

1 Installing the Router

ATLAS 50

11

Summary of Contents for ATLAS 50

Page 1: ...ATLAS 50 Installation Manual Copyright Teldat DM696 I Version 3 1 7 2015 Teldat S A Teldat S A Manual ATLAS 50 1...

Page 2: ...Teldat S A offers no warranty whatsoever for information contained in this manual Teldat S A is not liable for any direct indirect collateral consequential or any other damage connected to the deliv e...

Page 3: ...onfiguration 8 1 5 PMC PCI Cards 9 1 5 1 Procedure to install PMC cards 10 Appendix A Technical Information 12 A 1 Troubleshooting 12 A 2 Updating the software 12 A 3 Connectors 13 A 3 1 LAN FE x Conn...

Page 4: ...Table of Contents Teldat S A ii ATLAS 50...

Page 5: ...actual device Warning The equipment is intended to be installed by Service Personnel and only handled by qualified person nel If not the device may be damaged and malfunction This device contains elem...

Page 6: ...arefully Workplace Conditions Main Characteristics Excessive cold and heat should be avoided as should humidity and dust Direct exposure to sunlight should be avoided as well as other heat sources The...

Page 7: ...ected to the same power source This will avoid operating and premature aging prob lems of drivers and other components Fig 2 Power supply connection with external source To connect the power source to...

Page 8: ...its an tenna cables in the device Fig 5 Antenna connector for Wireless LAN 1 2 2 1 BRi Connection The BRI interface has a 4 wire RJ45 female connector in order to connect to the S bus coming from the...

Page 9: ...ust be positioned terminal resistance on if the router is the only element connected to the network terminal NT1 TR1 etc or it is in the last position on the ISDN S bus This is the configured default...

Page 10: ...2 2 3 Connecting for configuration The ATLAS 50 router has a RJ45 female connector on the front panel referred to as CONF which provides ac cess to the device local console In order to configure this...

Page 11: ...e it is not enabled or due to auto test failure GREEN Interface initialized and operating Flashing indicates frame activity YELLOW Interface in process of initialization BRI ISDN Interface OFF Physica...

Page 12: ...the steps below if you have to discard the whole configuration of the device for instance if you cannot re member the password Turn off the device through the ON OFF switch Using a screwdriver move mi...

Page 13: ...Aux stack used 0x124 Aux stack free 0x1EDC Running application Default configuration used Parsing text mode configuration Configuration parsed Initializing Press any key to get started On reaching thi...

Page 14: ...device Check that the board is clearly settled over the PMC connectors 8 Screw the PMC board to the posts using two screws with their corresponding washers Firmly tighten the screws without damaging...

Page 15: ...0000 Subs Device 0x0000 Slot 1 PCI device CardBus bridge Bus 0 Device 10 Function 0 Subs Vendor 0x0000 Subs Device 0x0000 Current production date 00 00 Current software license 12 15 Current serial nu...

Page 16: ...OFF position In this situation you may have to reload the device BIOS and the routing application The device is very slow in dis playing the application prompt Check that micro switch 3 is in the OFF...

Page 17: ...N 1 2 3 4 5 6 7 8 Tx input Tx input Rx output Rx output A 3 2 BRI Connector RJ45 ISDN RJ45 PIN ISDN 1 2 3 4 5 6 7 8 Tx output Rx input Rx input Tx output A 3 3 ANT Connectors PIN ANT Internal External...

Page 18: ...OM 2 Kbytes NVRAM 128 Kbytes LAN Interface PROTOCOLS Ethernet 802 3 N PORTS 1 1 SPEED 10 100 Mbps BaseT CONNECTOR RJ45 Female CABLE STP Length 3m Depending on the model Wireless LAN Interface STANDARD...

Page 19: ...T 5 A to 5 V DC 1 A to 12 V DC and 0 1 A to 12 V DC MAXIMUM POWER 30 W External Power Source INPUT VOLTAGE 100 240 V AC INPUT CURRENT 1 A INPUT FREQUENCY 50 60 Hz MAXIMUM POWER 45 VA Dimensions and We...

Page 20: ...and any additional steps established by law All the packing materials i e the cardboard box plastic and any other packaging together with the pieces making up an ATLAS 50 must be recycled complying wi...

Page 21: ...B 2 Translated Safety Warnings Connections 0 1 2 13 45678 69 5 67 9 7 781 3 31 631 551 1 1 1 Teldat S A Safety information ATLAS 50 17...

Reviews: