SG 10 - USER MANUAL 

Space Guard Series

 

 

Photoelectric light curtains 

 

Website:  www.telcosensors.com

 

 

Warning

 

V 1.4 Part Number: 0666220648

 

E-Mail:     [email protected] 

 

This device is not to be used for Personnel Protection in Machine 

Guarding Safety applications. This device does not include the self-

checking redundant circuitry necessary to allow its use in personnel 

machine guarding stand-alone safety applications. 

March 2019 edition 

 

Made in Denmark

 

Telco A/S reserves the right to make changes without prior notice 

 

 

tel 

EN 

Product Data 

 

Electrical Data 

 

SGT (Transmitter) 

SGR (Receiver) 

Supply voltage 

12 – 36 Vdc 

Max. Voltage ripple 

15 % (within supply range) 

Current consumption 

100 mA 

50 mA 

Max. output load 

200 mA 

Reverse polarity protected 

Yes 

Short circuit protected 

Yes 

Inductive load protection 

Yes 

 

Environmental Data 

Light immunity @ 5º incidence 

> 100.000 lux 

Temperature, operation 

-20 to + 65 ºC 

Sealing class 

Slim Line C-type profile: IP 67 

Slim Line A-type & Leading edge B-type profile: IP 54 

Marking 

 

 

Available Models 

 

Model 

Output 

Output 

Mode 

Time-out 

Function 

Sensing 

Range 

Transmitter  SGT 10-xxx-0xx-x1-x-0x-xx 

 

A & C profile: 

1 – 10m 

 

B profile: 

1 – 7.5 m 

 

Receiver 

SGR 10-xxx-0xx-B1-x-06-xx 

Solid 

State 

Relay 

Light/Dark 

Yes 

SGR 10-xxx-0xx-x1-x-07-xx 

No 

 

Connection

 

 

Wiring Diagrams

 

 

 

 

 

 

5 pole M12 male connector 

 

Transmitter Model 

Black wire  

connected to ( - ) 

Black wire  

not connected 

Black wire  

connected to ( + ) 

SGT 10-xxx-0xx-x1-x-

00

-xx  TX is not transmitting 

TX is transmitting 

TX is transmitting 

SGT 10-xxx-0xx-x1-x-

01

-xx  TX is not transmitting 

TX is transmitting 

TX is not transmitting 

SGT 10-xxx-0xx-x1-x-

02

-xx 

TX is transmitting 

TX is not transmitting 

TX is transmitting 

 

 

 

 

 

 

 

Transmitter SGT 10 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  Receiver SGR 10 output as NPN 

 

 

Receiver SGR 10 output as PNP 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Receiver SGR 10 with solid state relay output. 

 

Installation & Adjustments

 

 

Adjustment

 

No initial set up or adjustments are required, due the automatic signal-tracking (AST) feature, 

that automatically adjusts the gain of each individual beam on the system. 
Notice that the SG 10 system must not be placed on moving doors. 

Mount the transmitter (SGT) and receiver (SGR) facing each other and correctly aligned.  

Wire the sensor according to the wiring diagram. 

Make sure the load does not exceed 200 mA. 

Check for correct wiring before turning power on. Select Light/Dark output mode if 

required. 

When the power on indicator (green LED) is on, the system is operating. 

If the Status indicator (red LED) is constant on the SGR cannot see the SGT. 

Output Logic

 

Detection 

Output mode

 

Output 

status 

Output indicator 

(yellow led)

 

 

Present 

 

 

 

 

 

 

 

 

Dark operated (N.O.) 

(White wire connected to 

Blue wire) 

Closed 

On 

Light operated (N.C.) 

(White wire disconnected) 

Open 

Off 

 

Absent 

 

 

 

 

 

 

 

Dark operated (N.O.) 

(White wire connected to 

Blue wire) 

Open 

Off 

Light operated (N.C.) 

 (White wire disconnected) 

Closed 

On 

 

Time-out Function                                                                      

On models with timeout function up to 3 non-adjacent channels can be ignored when 

obstructed for more than 10 seconds: 

Receiver Model 

Non-adjacent channels which can be ignored 

SGR 10-xxx-028-B1-x-06-xx 

SGR 10-xxx-024-B1-x-06-xx 

SGR 10-xxx-020-B1-x-06-xx 

SGR 10-xxx-016-B1-x-06-xx 

SGR 10-xxx-012-B1-x-06-xx 

SGR 10-xxx-008-B1-x-06-xx 

 

Test Input                                                                                                                         

The SGT10 transmitter can be externally disabled and enabled via the black control wire for 

test purposes.  When the transmitter is disabled the receiver will switch the output. 

 

Indicators 

 

 

 

 

 

 

 

 

 

 

 

 

 

Troubleshooting 

Probable Reason 

Corrective Action 

1.

 Symptom: Status indicator (Red LED) on SGR is constant on. 

TX is not emitting. 

Check supply and cable to the SGT. 

SGT is disabled. 

Enable the SGT. 

The upper channel is blocked. 

Remove obstruction.  

The rails are out of sensing range 

Reduce the distance between the rails. 

On models with timeout function:  

Too many channels have been blocked or 

damaged (time-out function is activated). 

Remove obstruction or replace the faulty unit. 

 

2.

 Symptom: Status indicator (Red LED) is flashing but correct function of light curtain. 

On models with timeout function: time-out 

function is activated. 

 

Remove obstruction or replace the faulty unit. 

 

 

3.

 Symptom: Status indicator (Red LED) is flashing and output is activated in Dark Operated 

mode. Output is not activated in Light Operated mode. 
On models with timeout function: Two 

adjacent channels are blocked or 

damaged. 

Remove obstruction or replace the faulty unit. 

 

4.

 Symptom: Output indicator (Yellow LED) is flashing 

Severe electrical interference. 

Separate SGR and SGT supply cable from high 

voltage cables. 

Severe ambient light. 

Swap position of SGT and SGR. 

Cross talk from another light curtain. 

Swap position of SGT and SGR. 

Cross talk from a nearby HF strip light 

Swap position of SGT and SGR or remove the 

strip light. 

 

5.

 Symptom: Status indicator (Red LED) is not lit and output is activated in Dark Operated 

mode. Output is not activated in Light Operated mode. 
One or more beams are blocked or the 

rails are out of sensing range. 

Remove obstruction or reduce the distance 

between the rails. 

 

 

 

Red LED: Status indicator 

SGT                    SGR 

Yellow LED: Output indicator 

Green LED: Power on indicator 