Page 2: ...d health requisites as per the European Directive on Machine Safety This declaration is rendered null and void where the machine is modified without our written approval Machine AIR CONDITIONER Model...
Page 3: ...2 2 Open new hole 7 4 2 3 Power lead 8 4 3 Positioning the conditioner 9 4 4 Connecting the power lead 9 4 5 Installing the diffuser 10 5 ISTRUCTION FOR USE 10 5 1 Introduction 10 5 2 Preliminary chec...
Page 4: ...ed to read the entire manual and the reference documents this is the best way to ensure long lasting performance reliability and prevention of injury or damage Note the information contained in this p...
Page 5: ...nditioner identification plate is valid SILENT 12000H Refrigerating power 10950 BTU 3 15 kW N of fan speeds 3 Power supply 230 V 50Hz Consumption 6 6 A 230 V a c Peak current 32 A 0 15 sec Absorbed po...
Page 6: ...ring capacity greater than the weigh to be lifted 4 INSTALLATION 4 1 Preliminary Information Before installing the conditioner you must read these instructions thoroughly to prevent errors Incorrect i...
Page 7: ...as long as the port size is 395 x 395 mm fig 2 Proceed by removing the screws that fix the port to the roof and then removing the port itself Scrape off all the sealing material left around the rim of...
Page 8: ...ture on the roof protruding from the hole on the reinforcement frame by about 50 cm this additional length makes it easier to connect up to the air conditioner fig 6 Before making any electrical conne...
Page 9: ...oner until the four fixing threads are aligned with the square opening of the hole on the roof Insert from inside the camper the metallic frame align the seat of the diffuser with the rectangular air...
Page 10: ...roduction The manufacturer cannot be held liable for damage caused by improper use of the air conditioner The SILENT air conditioner consists of four main parts compressor which circulates the coolant...
Page 11: ...e maximum efficiency always keep external ventilation grilles clear 5 3 Control panel fig 12 Fan speed key fig 12 ref 1 Thermostat adjuster knob fig 12 ref 2 On off switch fig 12 ref 3 Menu key fig 12...
Page 12: ...high speed If one of the three fixed speeds is set the control panel always activates ventilation at that same speed If instead fan speed is set to AUT the control panel step by step fig 12 automatic...
Page 13: ...top by itself The steady symbol indicates that the compressor is running The flashing symbol indicates the stand by function during which the compressor is not running and is going to be started again...
Page 14: ...g power check by connecting up any other appliance or use a voltmeter 2 The compressor does not start but the fans are working ambient temperature is lower than 16 C set temperature higher than ambien...
Page 15: ...suitable detergent onto the heat exchangers evaporator and condenser and then rinse to remove impurities Check that the condensate drain holes are unobstructed Check that the seals are in good conditi...
Page 16: ...erstood that the purchaser has no right whatsoever to terminate the contract to claim damages for people or things to demand an extension of the warranty in case of any product defect or malfunction A...
Page 17: ...Compressor On K1 COMPRESSOR relay KC HOT relay M1 COMPRESSOR motor CN Connector electrical 11 poli MVC Condensing fan motor MVE Evaporating fan motor YC Solenoid pump heat PMX HIGH PRESSURE SWITCH ST2...
Page 18: ...SILENT 12000H 18 GB DRAWING FOR SPARE PARTS LIST SILENT 12000H...
Page 19: ...SILENT 12000H 19 GB...
Page 20: ...SILENT 12000H 20 GB...
Page 21: ...SILENT 12000H 21 GB...
Page 22: ...ation Befestigungsrichtseil Vaststellingsdwarslijn Transversal de fijaci n 12 03069 N 1 Scatola condensatore Condenser box Bo te de condensateur Kondensatorkasten Condensator doos Caja del condensador...
Page 23: ...ingsunit difusor Unidad de evaporacion 33 00013 N 1 Convogliatore aria Air conveyor Convoyeur d air Luftf rderwerk Lucht transportband Transportador del aire 34 05576 mt 2 Aerstop Rubber strip Joint c...
Page 24: ...d com Service Technique France 06 83 31 44 05 ESPA A NAUCCA CARAVANING S A Poligono Industrial CAN ROQUETA 2 Calle Can Lletget 2 08202 Sabadell Barcelona Espa a Tel 00 34 937 457 054 Fax 00 34 937 254...