5  INSTRUCTIONS FOR USE 

 

5.1  Introduction 

 

  The  power  supply  voltage  must 

never be less than 205V AC, with a stable 
frequency of 50Hz. 

 

 

Outside  the  specified  operating 

temperature range, the efficiency of the air 
conditioner is reduced considerably. 

 

The 

ICE  S  2800 

air  conditioner  consists  of 

nine main parts: 
 

 

compressor

, which circulates the coolant 

gas through the system. 

 

condenser

,  which  cools  the  coolant  by 

changing  it  from  a  gaseous  to  a  liquid 
state. 

 

evaporator

, which, cooled by the change 

of  state  of  the  coolant,  cools  the  air 
passing through it. 

 

two  fans

,  which  move  the  air  so  that  it 

passes  through  the  condenser  and 
evaporator 

 

solenoid  valve

,  which  switches  gas 

circulation  and  so  provides  a  cooling  or 
heating function 

 

remote  control 

to  program  the  desired 

function 

 

receiver, 

situated  in  the  diffuser,  which 

receives the remote control signals 

 

electronic  board, 

which  receives  the 

signals  from  the  receiver

 

and  transforms 

them  into  commands  for  the  various 
electrical 

components 

of 

the 

air 

conditioner. 

 
The 

ICE  S  2800

  provides  cold  air  during  the 

summer months and hot air in winter. 
If  the  vehicle  has  been  left  in  the  sun  for 
some  time  it  is  good  practice  to  open 
windows  and  doors  before  starting  the 
conditioner  so  as  to  release  the  build  up  of 
heat  in  the  interior;  once  indoor  temperature 
matches  outdoor  temperature  close  the 
windows  and  doors  and  start  the  air 
conditioner.  Subsequently,  only  open  doors 
and windows when necessary. 
 
 

5.2  Preliminary checks 

 
Before switching on the air conditioner for the 
very first time: 

  Check  that  condensate  drainage  holes 

are unobstructed. 

  Check that the power  supply  voltage  and 

frequency 

match 

the 

required 

specifications. 

  Check that  air  flow  through  relative  ducts 

and  vents  is  unobstructed.  To  ensure 
maximum efficiency always keep external 
ventilation grilles clear. 

 

  When  the  equipment  is  started  for 

the  first  time  with  the  remote  control,  the 
fan and compressor will also start within a 
few  seconds.  After  a  power-off,  upon  the 
next  power-on  the  compressor  will  only 
start  after  at  least  3  minutes  from  the 
power-off. 

 
 

5.3  Useful tips 

 

 

  Enhance  the  thermal  insulation  of  the 

camper  by  eliminating  any  fissures  and 
covering  glass  surfaces  with  heat-
reflecting curtains. 

  Avoid 

frequent 

opening/closing 

of 

windows unless necessary. 

  Select  a  suitable  temperature  and  airflow 

rate. 

  Adjust  the  outflow  vents  to  maximise 

comfort. 

  Never  close  both  adjustable  vents  when 

the conditioner is running. 

  Clean the diffuser filters periodically. 

  Do  not  obstruct  airflow  inlets/outlets  with 

fabric, paper or anything else. 

  Do  not  spray  water  inside  the  air 

conditioner. 

  Remove the  remote control  battery  if  you 

do not intend to use the conditioner  for a 
long period. 

  Periodically  check  that  the  condensate 

drain holes are not obstructed. 

  Periodically  check  that  external  intakes 

grilles  are  clean  so  as  to  maintain 
maximum air conditioner efficiency. 

  Clean  the  air  conditioner  with  detergent 

solutions  only;  never  use  petrol  or 
solvents. 

Summary of Contents for ice S2800

Page 1: ...MANUAL FOR INSTALLATION AND USER MANUAL v 001 May 2021...

Page 2: ...ffer in some details from the illustrations contained in this manual the safety and information regarding it are nevertheless guaranteed Graphic safety symbols are used in this document to identify va...

Page 3: ...Do not insert anything into the air vents of the diffuser or the condenser fan In the event of fire do not open the top cover of the AC unit and only use approved fire extinguishers Do not attempt to...

Page 4: ...rendered null and void in the event of incorrect assembly improper use or modifications made to the machine without our written approval Machine AIR CONDITIONER Model ICE S 2800 Serial n Reference dir...

Page 5: ...minary checks 12 5 3 Useful tips 12 5 4 Installing the batteries in the remote control 13 5 5 Information on using the Remote Control 13 5 6 Remote Control description and functions 13 5 7 Remote Cont...

Page 6: ...r cooling 990 Watt Power consumption for heating 950 Watt Cooling capacity 2500 Watt Heating capacity 2450 Btu h Operating temperature 2 48 C Internal temperature adjustment range 16 31 C Internal fan...

Page 7: ...the symbol on the packaging Stacking more than five packaged air conditioners can damage the conditioners themselves and put personnel at risk of injury 3 2 Weight Weight of ICE S 2800 including packa...

Page 8: ...terior which might obstruct diffuser attachment fig 1 ref 6 or the outflow of cool air from the adjustable vents fig 1 ref 8 The air conditioner may be installed in one of two different ways by using...

Page 9: ...ectrical wires fig 4 ref 2 Fix a reinforcement frame around the opening fig 5 4 2 3 Power lead A 3 core cable with a 2 5 mm cross section live neutral earth must be routed for the power supply of the...

Page 10: ...ing damage to the roof Bring the air conditioner onto the roof fig 7 ref 2 and without scraping it position it over the 360 x 360 mm opening previously lined with sealant Correct alignment of the air...

Page 11: ...multiple fittings The purpose of the fitting is to form a sealed channel to connect the diffuser inlet port to the outlet port on the bottom of the air conditioner Open the two doors on the diffuser...

Page 12: ...air conditioner Subsequently only open doors and windows when necessary 5 2 Preliminary checks Before switching on the air conditioner for the very first time Check that condensate drainage holes are...

Page 13: ...ontrol for some time remove the batteries If the signal transmission sound is no longer audible in the internal unit or the transmission symbol is no longer clearly visible on the display screen the b...

Page 14: ...ting mode 4 Ventilation mode 5 Timer start time only visible if the timer has been activated 6 Timer stop time only visible if the timer has been activated 7 System time 8 Temperature setting 9 Courte...

Page 15: ...ys TEMP and TEMP 4 Press the FAN key several times until you reach your required ventilation setting 5 12 Heating operation mode 1 Press the On Off key 2 Press the MODE key several times until the dis...

Page 16: ...temperature setting 24 C 6 MAINTENANCE 6 1 Cleaning the filters To ensure full efficiency of the air conditioner clean the diffuser filters by washing them with a neutral detergent solution allow them...

Page 17: ...even after the exchangers have been cleaned check the refrigerating gas load 6 4 Opening the external lid The external lid in ABS is attached to the base by 6 re usable rivets To remove them proceed a...

Page 18: ...n of this appliance are recyclable In the event of disposal it is advisable to bring the unit to a specialist workshop or designated waste collection centre Waste materials must not be dispersed into...

Page 19: ...period shall end no later than 14 months 16 months if delivered outside of Europe after ex factory delivery In any case the costs of lubricants and consumables shall be charged Any transport expenses...

Page 20: ...itor C4 Condenser fan capacitor C5 Compressor run capacitor EvGAS 4 way solenoid valve MC Compressor motor VC Condenser fan motor VE Evaporator fan motor CTP condenser temperature probe ETP Evaporator...

Page 21: ...Rev 001 ICE S 2800 21 10 SPARE PARTS LIST...

Page 22: ...ICE S 2800 Rev 001 22...

Page 23: ...ompresor 13 06180 n 1 Scatola condensatore Bo te de condensateur Doos van de condensator Condenser box Kondensatorkasten Caja del condensador 14 06181 n 1 Coperchio del condensatore Couvercle du conde...

Page 24: ...jeta electr nica 74 06239 n 1 Condotto aria adesivo rettangolare per diffusore Conduit d air adh sif rectangulaire pour diffuseur Rechthoekige lijm luchtkanaal voor diffuser Rectangular adhesive air d...

Page 25: ...Rev 001 ICE S 2800 25 Notes...

Page 26: ...ICE S 2800 Rev 001 26 Notes...

Page 27: ...Rev 001 ICE S 2800 27 Notes...

Page 28: ...ICE S 2800 Rev 001 28...

Reviews: