the
5XT
directly to A channel
input
connector.
When
the adjustments to
A channel have been
completed connect the cable from the Type
105
to
the B channel input
connector
and
proceed
with the
adjustments
for
this channel.
See the
charts below
for the adjustments to
each channel. Note: When the
.5 VOLTS/CM
position
is
reached the 5XT attenuator must
be
removed.
A
Channel
Adjustments
volts
/
cm
Sw
i
tch
Adj
for Optimum
Square
Corner
Adj for Optimum
Flat Top
.1
C3311C
C3311B
.2
C3312C
C3312B
.5
C3313C
C3313B
1
C3314C
C3314B
2
C3315C
C3315B
5
C3316C
C3316B
10
C3317C
C3317B
20
C3318C
C3318B
B
Channel Adjustments
VOLTS/CM
Switch
Adj
for
Optimum
Square
Corner
Adj
for
Optimum
Flat Top
.1
C4311C
C4311B
.2
C4312C
C4312B
.5
C4313C
C4313B
1
C4314C
C4314B
2
C4315C
C4315B
5
C4316C
C4316B
10
C4317C
C4317B
20
C4318C
C4318B
14.
H.
F. Compensations
Set oscilloscope controls as follows:
TIME/CM
.2
MICROSEC
Set plug-in
controls as follows:
VOLTS/CM (A and
B)
.1
MODE
B
ONLY
Connect the Type 107 Square-Wave
Gener
ator
to the channel B
input
connector of the
Type
CA Unit, installing the Terminating
Resistor
between the
P52
cable
and the plug-in
unit. Adjust the Approximate Amplitude
control
on
the Type 107
for
3 cm
of vertical deflection
on
the
crt
of the oscilloscope.
Adjust the
Approximate
Frequency control for an approxi
mate output frequency of 450 kc.
Now
adjust L3364,
L4374, L4362, L4372,
L4334
and L4354 for an optimum square
comer
with
no
overshoot on the square-wave
signal.
Set the
MODE switch of the Type CA Unit
to
A
ONLY and connect the Type 107, in the
same
manner
as
above, to the A channel
vertical
input connector. For channel A
adjust
L3362,
L3372, L3354 and L3334 for an optimum
square comer with no
overshoot on the square
wave
signal.
Note
When you
are finished check to
see
that
the plugs
in the coils are
all
approximately the same depth
inside
the
coil
form. If they aren't
readjust until
this
condition is
obtained.
15. Frequency
Response
The
oscilloscope controls should
be set
as
follows.
TRIGGERING
MODE AC LF REJECT
TIME/CM
.1
MILLISEC
STABILITY
full
right (cw)
The plug-in controls
will be set to:
VOLTS/CM (A and B)
.05
MODE
B ONLY
Ad
just the Type 190 Constant Amplitude
Signal
Generator to obtain an output frequency
of 50 kc. Attach the Type 190
to the B channel
vertical input connector installing
the 5XT
between the 190 attenuator box and the plug
in. Adjust the Output Amplitude control on the
Type
190
to obtain exactly 3 cm of vertical
deflection on
the crt. Adjust the Type 190
for
an output frequency
of 24 mc making sure
not
to move the
Output
Amplitude
control.
There
should
now be at least 2.1 cm of vertical
deflection remaining.
Turn
the
MODE switch to A ONLY
and
connect
the Type
190 to the B channel
vertical
input
connector. Make
sure not
to disturb the
control
settings of the Type 190 when making
this
transfer. The A
channel should also have
at
least
2.1 cm of vertical deflection.
AA
Calibration -
Type CA
5-5