Reference
Options
Comments
↑
↓
Moves the
fi
eld selection highlight up or down through the list. Use
the multipurpose knob to change the value of the selected
fi
eld
Set Date and Time
Updates the oscilloscope with the speci
fi
ed date and time
Cancel
Closes the menu and returns to the previous menu without saving
any changes
Self Calibration.
The Do Self Cal (self calibration) routine optimizes the
oscilloscope accuracy for the ambient temperature. For maximum accuracy,
perform a self calibration if the ambient temperature changes by 5 °C (9 °F )
or more. For accurate calibration, power on the oscilloscope and wait twenty
minutes to ensure it is warmed up. Follow the directions on the screen.
Factory calibration uses externally-generated voltages, and requires specialized
equipment. The recommended interval is one year. See
Contacting Tektronix
on the copyright page for information on having Tektronix perform a Factory
Calibration of your oscilloscope.
File Utilities
You can use the File Utilities menu to do the following tasks:
List the contents of the current folder
Select a
fi
le or folder
Navigate to other folders
Create, rename, and delete
fi
les and folders
Format the CF card
Options
Comments
Navigates to the selected CF card folder. Use the multipurpose
knob to select a
fi
le or folder, then select the Change Folder
menu option to navigate to the selected folder.
Change Folder
To return to the previous folder, select the
↑
Up folder item and
then select the Change Folder menu option.
New Folder
Creates a new folder in the current folder location, named
NEW_FOL, and displays the Rename menu for changing the
default folder name.
Rename (
fi
lename or
folder)
Displays the Rename screen to rename a folder or
fi
le, described
next.
Delete (
fi
lename or
folder)
Deletes the selected
fi
le name or folder; a folder must be empty
before you can delete it.
Con
fi
rm Delete
Displays after pressing Delete, to con
fi
rm a
fi
le delete action.
Pressing any button or knob other than Con
fi
rm Delete cancels
the
fi
le delete action.
TPS2000B Series Digital Oscilloscope User Manual
119
Summary of Contents for TPS2012B
Page 1: ...xx TPS2000B Series Digital Storage Oscilloscope ZZZ User Manual P071273302 071 2733 02...
Page 2: ......
Page 3: ...TPS2000B Series Digital Storage Oscilloscope ZZZ User Manual xx www tektronix com 071 2733 02...
Page 8: ......
Page 22: ...Compliance information xiv TPS2000B Series Digital Oscilloscope User Manual...
Page 26: ...Preface xviii TPS2000B Series Digital Oscilloscope User Manual...
Page 40: ...Getting Started 14 TPS2000B Series Digital Oscilloscope User Manual...
Page 93: ...Math FFT TPS2000B Series Digital Oscilloscope User Manual 67...
Page 96: ...Math FFT 70 TPS2000B Series Digital Oscilloscope User Manual...
Page 170: ...Appendix D Cleaning 144 TPS2000B Series Digital Oscilloscope User Manual...