Performance veri
fi
cation
14.
Disconnect the cable from the
BLACK 1
connector of the SPG8000 under
test and connect it to the
BLACK 2
connector of the SPG8000 under test.
15.
Repeat steps 5 through 13 for the BLACK 2 output.
16.
Disconnect the cable from the
BLACK 2
connector of the SPG8000 under
test and connect it to the
BLACK 3
connector of the SPG8000 under test.
17.
Repeat steps 5 through 13 for the BLACK 3 output.
Black output bit integrity
test
Perform the following test to insure that all the bits in the black generators are
working correctly. This test should be performed in factory mode. (See page 19,
1.
Connect a cable from the
BLACK 1
output of the SPG8000 under test to the
CMPST A input on the video monitor, and terminate the loopthrough with a
75
Ω
terminator.
Figure 7: Setup for black output bit integrity test
2.
Activate the waveform monitor composite input.
3.
Press the
BLACK
button on the SPG8000 until you see
BLACK 1 :
FORMAT
.
4.
Use the left (
◄
) or right (
►
) arrow button to select
NTSC
.
5.
Press the
ENTER
button.
6.
Use the up (
▲
) arrow button to select
CALIBRATION
.
7.
Press the
ENTER
button to select
Amplitude Calibration
.
NOTE.
Write down the calibration setting (AMPL. DAC number) in case you
need to restore it later.
8.
Press the right (
►
) arrow until you see the
Ramp HPF
ramp signal.
44
SPG8000 Speci
fi
cations and Performance Veri
fi