R-GPIB Commands
Variable: Value TDSUSB2 Command Arguments and Queries- Results
Variable Name
Valid values
Function
Querying Form
Sets the result variables with
appropriate result values for
that particular test
resultFor
{eye, sigrt, jk, kj, con, eop,
After being set to a measurement
value, the query returns "Busy"
until the results are refreshed.
Returns the selected
measurement for result querying
eopbit, cross, rt, ft, mon, in,
pphost, pphost2, pphost3,
ppdevice1,ppdevice2, resume,
suspend, rfr, rfs,
chirphost1, chirphost2,
chirpdevice1}
reset
{Result}
Clears the active
measurements results
Statistical results-Basic statistics applicable for all SQC measurements
measUnits
Units string for the measurement
(for example “s” - seconds is the
unit for Period)
max
Maximum value of the
measurement
mean
Mean value of the result
min
Minimum value of the
measurement
pkpk
Peak-to-peak value of the
measurement
rms
RMS value of the result
population
Population (number of)
measurements used to calculate
the current statistics
stdDev
Standard deviation measurement
set
status
{Pass, Fail, Conditional Pass}
Returns Pass/Fail result for the
selected SQC measurement
Pass/Fail Status
eyeStatus
{Pass, Fail, Conditional Pass}
Returns the eye diagram
measurement
sqcOverallStatus
{Pass, Fail, Conditional Pass}
Returns the overall SQC
measurement result
Inrush
inCharge
Returns the inrush charge value
inCap
Returns the inrush capacitance
value
inStatus
{Pass, Fail, Conditional Pass}
Returns the Pass/Fail status of
inrush measurement
152
TDSUSB2 Universal Serial Bus Measurement Package
Summary of Contents for TDSUSB2
Page 24: ...Getting Started 10 TDSUSB2 Universal Serial Bus Measurement Package...
Page 32: ...Installation 18 TDSUSB2 Universal Serial Bus Measurement Package...
Page 61: ...Operating Basics TDSUSB2 Universal Serial Bus Measurement Package 47...
Page 76: ...Taking Measurements 62 TDSUSB2 Universal Serial Bus Measurement Package...
Page 90: ...Tutorial 76 TDSUSB2 Universal Serial Bus Measurement Package...
Page 160: ...Application Examples 146 TDSUSB2 Universal Serial Bus Measurement Package...
Page 230: ...Measurement Algorithms 216 TDSUSB2 Universal Serial Bus Measurement Package...
Page 250: ...Glossary 236 TDSUSB2 Universal Serial Bus Measurement Package...