Speci
fi
cations
Table 9: Nominal and typical ampli
fi
er characteristics (cont.)
Installed probe
Parameter
TCP312A
TCP305A
TCP303
TCP404XL
DC (continuous)
5 A
25 A
25 A
—
DC (noncontinuous)
N/A
N/A
N/A
—
RMS (sinusoidal)
3.5 A
17.7 A
17.7 A
—
Peak Pulse
50 A
50 A
500 A
—
Input Voltage
100-240 VAC (±10%), 47 Hz to 440 Hz, single phase
Maximum Power
50 Watts maximum
Fuse Rating
3.15 AH, 250 V (Not operator-replaceable.)
1
Includes probe, ampli
fi
er, and TEKPROBE-to-TEKPROBE interface cable or 012-0117-xx BNC cable.
Mechanical Characteristics
Table 10: TCPA300 and TCPA400 mechanical characteristics
Parameter, nominal
Characteristic
Length
173 mm (6.8 in)
Width
91.4 mm (3.6 in)
Height
167 mm (6.6 in)
Weight
1.14 kg (2.5 lb)
TCPA300/400 Ampli
fi
ers and TCP300A/400 Series Current Probes User Manual
51
Summary of Contents for TCP300A
Page 2: ......
Page 6: ......
Page 18: ...Preface xii TCPA300 400 Amplifiers and TCP300A 400 Series Current Probes User Manual...
Page 34: ...Getting Started 16 TCPA300 400 Amplifiers and TCP300A 400 Series Current Probes User Manual...
Page 78: ...Specifications 60 TCPA300 400 Amplifiers and TCP300A 400 Series Current Probes User Manual...