Important safety information

This manual contains information and warnings that must be followed by the user for safe operation and to keep the product in a safe
condition.

To safely perform service on this product, see the Service safety summary that follows the General safety summary.

General safety summary

Use the product only as specified. Review the following safety precautions to avoid injury and prevent damage to this product or any
products connected to it. Carefully read all instructions. Retain these instructions for future reference.

This product shall be used in accordance with local and national codes.

For correct and safe operation of the product, it is essential that you follow generally accepted safety procedures in addition to the safety
precautions specified in this manual.

The product is designed to be used by trained personnel only.

Only qualified personnel who are aware of the hazards involved should remove the cover for repair, maintenance, or adjustment.

Before use, always check the product with a known source to be sure it is operating correctly.

This product is not intended for detection of hazardous voltages.

Use personal protective equipment to prevent shock and arc blast injury where hazardous live conductors are exposed.

While using this product, you may need to access other parts of a larger system. Read the safety sections of the other component manuals
for warnings and cautions related to operating the system.

When incorporating this equipment into a system, the safety of that system is the responsibility of the assembler of the system.

To avoid fire or personal injury

Use proper power cord

Use only the power cord specified for this product and certified for the country of use.

Ground the product

This product is grounded through the grounding conductor of the power cord. To avoid electric shock, the
grounding conductor must be connected to earth ground. Before making connections to the input or output
terminals of the product, ensure that the product is properly grounded. Do not disable the power cord
grounding connection.

Ground-referenced
oscilloscope use

Do not float the reference lead of this probe when using with ground-referenced oscilloscopes. The
reference lead must be connected to earth potential (0 V).

Power disconnect

The power cord disconnects the product from the power source. See instructions for the location. Do not
position the equipment so that it is difficult to operate the power cord; it must remain accessible to the user
at all times to allow for quick disconnection if needed.

Use proper AC adapter

Use only the AC adapter specified for this product.

Connect and disconnect
properly

Do not connect or disconnect probes or test leads while they are connected to a voltage source.

Use only insulated voltage probes, test leads, and adapters supplied with the product, or indicated by
Tektronix to be suitable for the product.

Observe all terminal ratings

To avoid fire or shock hazard, observe all rating and markings on the product. Consult the product manual
for further ratings information before making connections to the product. Do not exceed the Measurement
Category (CAT) rating and voltage or current rating of the lowest rated individual component of a product,
probe, or accessory. Use caution when using 1:1 test leads because the probe tip voltage is directly
transmitted to the product.
Do not apply a potential to any terminal, including the common terminal, that exceeds the maximum rating
of that terminal.

Important safety information

TBS1000C Series Digital Storage Oscilloscope Service Manual

7

Summary of Contents for TBS1000C Series

Page 1: ...TBS1000C Series Digital Storage Oscilloscope Service Manual P077158401 077 1584 01...

Page 2: ......

Page 3: ...TBS1000C Series Digital Storage Oscilloscope Service Manual Register now Click the following link to protect your product www tek com register 077 1584 01...

Page 4: ...ued and pending Information in this publication supersedes that in all previously published material Specifications and price change privileges reserved TEKTRONIX and TEK are registered trademarks of...

Page 5: ...ion and cleaning 12 General care 12 Interior cleaning 12 Exterior cleaning 12 Exterior inspection 12 Interior inspection 13 Cleaning procedure interior 13 Lubrication 14 Adjustments 15 Replaceable par...

Page 6: ...t 13 Table 2 Internal inspection checklist 13 Table 3 Replaceable parts list 17 Table 4 Replaceable parts LCD Front panel Front case Power supply Main board and Rear case 18 List of Tables TBS1000C Se...

Page 7: ...and certified for the country of use Ground the product This product is grounded through the grounding conductor of the power cord To avoid electric shock the grounding conductor must be connected to...

Page 8: ...als before you clean the product Provide proper ventilation Refer to the installation instructions in the manual for details on installing the product so it has proper ventilation Slots and openings a...

Page 9: ...ice procedures Read this Service safety summary and the General safety summary before performing any service procedures To avoid electric shock Do not touch exposed connections Do not service alone Do...

Page 10: ...ut the nature of the potential hazards and any actions which have to be taken to avoid them This symbol may also be used to refer the user to ratings in the manual The following symbols may appear on...

Page 11: ...al available on the Tektronix Web site Go to www tektronix com manuals and search for the user manual for your product available in 11 languages Programmer Commands The oscilloscope programmer manual...

Page 12: ...and disconnect it from line voltage before performing any procedure that follows Exterior cleaning CAUTION Avoid the use of chemical cleaning agents which might damage the plastics used in this oscill...

Page 13: ...oscilloscope Table 2 Internal inspection checklist Item Inspect for Repair action Circuit boards Loose broken or corroded solder connections Burned circuit boards Burned broken or cracked circuit run...

Page 14: ...replaced as an assembly if significant moisture or debris become trapped inside Cotton tipped applicators and lint free rags moistened in isopropyl alcohol and or deionized water offer the best clean...

Page 15: ...test equipment signal sources and measuring equipment to verify the performance of the instrument To determine if an adjustment is required use the Performance Verification procedure in the TBS1000C S...

Page 16: ...ision level of the part For some parts in this manual you will find the letters XX in place of the revision level number When you order parts Tektronix will provide you with the most current part for...

Page 17: ...arated from the description by a colon Because of space limitations an item name may sometimes appear as incomplete Use the U S Federal Catalog handbook H6 1 for further item name identification Abbre...

Page 18: ...panel board 8 131 6417 XX 1 Contact Electrical 9 220 0265 XX 3 BNC nuts 10 210 1039 XX 3 BNC locking washer 11 441 2909 XX 1 Chassis ASSY 12 211 1273 XX 6 Screw Threaded 13 870 1704 XX 1 Main PCB ass...