background image

xx

MTM400 and MTM400A

DTV Monitors

RUI v3.x Upgrade

ZZZ

Technical Reference

*P077017402*

077-0174-02

Summary of Contents for MTM400

Page 1: ...xx MTM400 and MTM400A DTV Monitors RUI v3 x Upgrade ZZZ Technical Reference P077017402 077 0174 02...

Page 2: ......

Page 3: ...MTM400 and MTM400A DTV Monitors RUI v3 x Upgrade ZZZ Technical Reference xx www tektronix com 077 0174 02...

Page 4: ...this publication supersedes that in all previously published material Specifications and price change privileges reserved TEKTRONIX and TEK are registered trademarks of Tektronix Inc FlexVuPlus is a...

Page 5: ...taxes and any other charges for products returned to any other locations This warranty shall not apply to any defect failure or damage caused by improper use or improper or inadequate maintenance and...

Page 6: ......

Page 7: ...ration 8 User Documentation 8 Upgrades 9 RUI Control Equivalents 10 Reverting the RUI 15 Requirements 15 RUI Version 3 x to Version 3 0 Procedure 16 RUI Version 3 0 to Version 2 6 1 Procedure 19 Comma...

Page 8: ...Table of Contents ii MTM400 and MTM400A RUI v3 x Upgrade Technical Reference...

Page 9: ...d access to all information Differences between the two RUIs include The MTM400 hot spot view featuring device and stream buttons is no longer displayed The device and stream features have been integr...

Page 10: ...ion 3 x of the RUI The menu bar toolbar and status bar while visually different contain options and buttons similar in function to those in the MTM400 The main viewing areas of the window is divided i...

Page 11: ...iew two top level views are selected using tabs FlexVuPlus and Analysis You can customize the FlexVuPlus display to contain the analysis views of your choice The main analysis views are Programs Tests...

Page 12: ...tups will be remembered between DTV monitor sessions With a virtually unlimited variety of stream monitoring displays from which users can choose this exceptional flexibility enables the DTV monitor t...

Page 13: ...ement of a program within the transport stream Red LEDs indicate that there are current errors in the stream amber LEDs indicate that errors have occurred but are now clear and green LEDs indicate tha...

Page 14: ...am information DVB service information SI and ATSC PSIP ISDB program and system protocol information The tables are grouped together by function and hyperlinks enable you to quickly access related inf...

Page 15: ...t trends Trend graphs use accumulated readings to represent trends in selected readings for up to a week Also available are an Event Log and a Parameter view The Interface tab is displayed only when a...

Page 16: ...vel operational overviews MTM400A IPM400A and RFM300 Read This First 071 2654 xx Contains information about known operational issues MTM400A IPM400A and RFM300 Technical Reference 077 0175 xx Contains...

Page 17: ...GE MTM4UP GE Ethernet Interface With 10 100 1000Base T RJ 45 Electrical Port MTM4FGE Opt SX MTM4UP SX 1000Base SX Short Wavelength Optical port with LC connector Multi Mode 850 nm MTM4FGE Opt LX MTM4U...

Page 18: ...ams button in the button bar Select the desired Program Select the Pie Chart button on the right hand Summary tab Status Click the Tests button in the button bar Status is shown in the Tests tree and...

Page 19: ...n in the button bar Select the desired test in the tree Associated PIDs view on the right shows PIDs for the test Set PID bit rate limits Click the PIDs button in the button bar Right click the requir...

Page 20: ...lect the desired table in the tree Select the SI Repetition Graphs tab on the right hand side SI Tables SI Tree view Click the SI PSI button in the button bar The SI PSI tree structure is shown in the...

Page 21: ...n button on the toolbar Select the Schedule Management page Enable Thumbnails Click the Configuration button on the toolbar Select the Stream page Config SI Parameter Processing ISDB only Click the Co...

Page 22: ...desired graph Controls Click the Interface button on the toolbar In the dialog edit the parameters for the desired preset press Apply to see the effects without closing the dialog Input Card Readings...

Page 23: ...D ROM See page 22 Command Line Firmware Downgrade CAUTION If you have the GE option GbE interface installed in the MTM400A DTV monitor you must use the Command Line Firmware Upgrade process See page 2...

Page 24: ...plorer 2 In the Web browser address bar enter the IP address or network name of the MTM400 or MTM400A monitor See Figure 3 For example http TSMonitor01 or http 192 158 201 105 After you press the Ente...

Page 25: ...dialog box click Start to initiate the firmware installation 7 When the firmware upload is complete a Firmware upload complete message is displayed See Figure 5 As stated in the message the uploaded...

Page 26: ...will not be listed in the Configure Interface dialog box until the device MTM400A has been reset 1 Allow sufficient time for the reprogramming to complete this can be up to 30 minutes 2 Open the RUI a...

Page 27: ...e MTM400 RUI can be opened you must disable the Java Runtime Environment in the Internet Explorer If you attempt to open the MTM400 RUI before disabling the Java Runtime Environment the following mess...

Page 28: ...me Environment if you still receive the message Microsoft Java Virtual Machine required to run application you may need to reinstall the Microsoft Virtual Machine This is available on the Internet or...

Page 29: ...ecially if the login password was changed from the factory default value the RUI v2 6 1 may be inaccessible In this situation you must clear the NVRAM and reassign the IP address of the instrument The...

Page 30: ...u are advised to locate the upgrade program mtmfwuploader exe and copy it to the temporary directory containing the firmware upgrade file s 5 From the Windows desktop open the Command window Start Run...

Page 31: ...6 See page 19 Troubleshooting The progress indicator following the Waiting for interface programming to complete message may go beyond 100 If this happens do the following steps 1 Ensure that the sign...

Page 32: ...om Table 4 RUI v2 6 1 product documentation Document Tektronix part number User manual 071 1224 xx English 071 1538 xx Japanese Technical reference 071 1560 xx Release notes 071 1564 xx RUI v3 0 Produ...

Reviews: