MIL-STD-1553 bus trigger
You can trigger on
Sync
,
Command
,
Status
,
Data
,
Time (RT/IMG)
, or
Error
.
If you are setting up a MIL-STD-1553 trigger and have made a
Trigger On
selection of
Command
, push
RT Address
on the lower menu to enter specific
values of
RT Address
to trigger on. Push
Command Word Details
on the lower
menu to enter the
T/R bit
value,
Subaddress/Mode
value,
Word Count/Mode
Code
value, and
Parity
value.
If you are setting up a MIL-STD-1553 trigger and have made a
Trigger On
selection of
Status
, push
RT-Address
on the lower menu to enter specific values
of
RT Address
to trigger on. Push
Status Word Bits
on the lower menu to enter
values for
Message Error (bit 9)
,
Instr. (bit 10)
,
Service Req. (bit 11)
,
BCR
(bit 15)
,
Busy (bit 16)
,
Subsystem Flag (bit 17)
,
DBCA (bit 18)
,
Terminal
Flag (bit 19)
and
Parity
.
If you are setting up a MIL-STD-1553 trigger and have made a
Trigger On
selection of
Data
, push
Data
on the lower menu to enter specific
Data
values,
and the
Parity
value.
If you are setting up a MIL-STD-1553 trigger and have made a
Trigger On
selection of
Time (RT/IMG)
, push
Trigger When
on the lower menu to set the
trigger condition. Push
Times
on the lower menu to set the
Maximum
and
Minimum
times.
If you are setting up a MIL-STD-1553 trigger and have made a
Trigger On
selection of
Error
, push l
Error Type
on the lower menu to select the type of
error to trigger on.
Data value matching
You can trigger on a specific data value for RS-232 bytes. If you defined an end-
of-packet character to use for RS-232 bus decoding, you can use the same end-of-
packet character as a data value for trigger data matching. To do so, choose the
Tx End of Packet or the Rx End of Packet character as the Trigger On selection.
You can also trigger on a specific data value for other buses.
Parallel bus trigger data matching
Optimum parallel bus trigger performance is achieved by using only analog
channels or only digital channels.
Trigger setup
62
MDO4000C Series Oscilloscope User Manual
Preliminary
Summary of Contents for MDO4000C Series
Page 2: ...P r e l i m i n a r y...
Page 20: ...Compliance Information xvi MDO4000C Series Oscilloscope User Manual P r e l i m i n a r y...
Page 74: ...Acquire the signal 52 MDO4000C Series Oscilloscope User Manual P r e l i m i n a r y...
Page 140: ...Save and recall information 118 MDO4000C Series Oscilloscope User Manual P r e l i m i n a r y...