Get Acquainted with the Instrument
Identifying Items in the Digital Voltmeter Display
1.
Measurement type (AC+DC RMS, DC, AC RMS, or Frequency)
2.
Numerical value of the current measurement
3.
Graphic (min, max, value,
fi
ve-second rolling range)
The number on the left side of the graphic’s linear scale is the minimum value of the range (e.g. 0.000 V).
The number on the right side of the graphic’s linear scale is the maximum value of the range (e.g. 400.0 mV).
The gray bar shows the
fi
ve second rolling average of measurements.
The inverted triangle shows the location on the scale of the current measurement value.
4.
Minimum measurement value recorded since you powered on the instrument or since you last pushed the
Reset
DVM Statistics
menu item.
5.
Maximum measurement value recorded since you powered on the instrument or since you last pushed the
Reset
DVM Statistics
menu item.
6.
Average of all measurement values recorded since you powered on the instrument or since you last pushed the
Reset
DVM Statistics
menu item.
7.
Frequency
NOTE.
An “Over bandwidth” message appears for voltage measurements
≥
10 kHz. An “Under bandwidth” message
appears for voltage measurements
≤
10 Hz. A “?” message appears next to min or max measurements that have gone
out of bounds. Push
Reset DVM Statistics
to remove the “?” from the display.
Taking Digital Voltmeter Measurements
MDO3000 Series Oscilloscopes User Manual
51
Summary of Contents for MDO3012
Page 1: ...x MDO3000 Series Mixed Domain Oscilloscopes ZZZ User Manual P077096802 077 0968 02...
Page 2: ......
Page 3: ...MDO3000 Series Mixed Domain Oscilloscopes ZZZ User Manual xx www tek com 077 0968 02...
Page 10: ...Table of Contents iv MDO3000 Series Oscilloscopes User Manual...
Page 236: ...Appendix D OpenSSL License 214 MDO3000 Series Oscilloscopes User Manual...