Installation
TPP1000
Probe
Setup
SN:
000001
Atten: 10X
7.
Notice that the compensation status starts
as
Default
.
Compen-
sation
Status
Default
8.
Push
Compensate probe
and follow the
instructions that appear on the display.
Compen-
sate probe
for 1
Measure
Current
Yes |
No
When compensating TPP0250/TPP0500B/TPP1000 probes on the MDO3000 Series oscilloscopes:
Each compensation generates values for a speci
fi
c probe and channel combination. If you want to use the probe on
another channel and desire to compensate the new probe-channel pair, you must run a new set of compensation steps.
Each channel can store compensation values for 10 individual probes. If you try to compensate an 11th probe on a
channel, the oscilloscope will delete the values for the least recently used probe and add the values for the new probe.
The oscilloscope will assign default compensation values to a TPP0250, TPP0500B or TPP1000 probe connected to
the
Aux In
channel.
NOTE.
A factory calibration will delete all stored compensation values
NOTE.
A probe compensation failure is most likely due to intermittent connection of the probe tip or ground connection
during the probe compensation operation. If a failure occurs, the oscilloscope will re-use the old probe compensation values,
if they existed prior to the failed probe compensation operation.
Compensating a non-TPP0250, non-TPP0500B or non-TPP1000 Passive
Voltage Probe
Whenever you attach a passive voltage probe for the
fi
rst time to any input channel, compensate the probe to match it to
the corresponding oscilloscope input channel.
If you are interested in using the automatic probe compensation procedure described above for the TPP0250, TPP0500
and TPP1000 probes (See page 11,
Compensating a TPP0250, TPP0500B or TPP1000 Passive Voltage Probe
.). On a
non-TPP0250/TPP0500B/TPP1000 Tektronix passive probe, check the instruction manual for your probe to see if it quali
fi
es.
Otherwise, to properly compensate your passive probe:
1.
Follow the steps for the functional
check. (See page 10,
MDO3000 Series Oscilloscopes User Manual
13
Summary of Contents for MDO3012
Page 1: ...x MDO3000 Series Mixed Domain Oscilloscopes ZZZ User Manual P077096802 077 0968 02...
Page 2: ......
Page 3: ...MDO3000 Series Mixed Domain Oscilloscopes ZZZ User Manual xx www tek com 077 0968 02...
Page 10: ...Table of Contents iv MDO3000 Series Oscilloscopes User Manual...
Page 236: ...Appendix D OpenSSL License 214 MDO3000 Series Oscilloscopes User Manual...