Models 707B and 708B Switching Matrix Reference Manual
Section 7: TSP command reference
707B-901-01 Rev. B / January 2015
7-61
digio.trigger[N].wait()
This function waits for a trigger.
Type
TSP-Link accessible
Affected by
Where saved
Default value
Function
Yes
Usage
triggered
= digio.trigger[
N
].wait(
timeout
)
triggered
The value
true
if a trigger is detected, or
false
if no triggers are detected during
the timeout period
N
Digital I/O trigger line (1 to 14)
timeout
Timeout in seconds
Details
This function pauses for up to
timeout
seconds for an input trigger. If one or more trigger events are
detected since the last time
digio.trigger[
N
].wait()
or
digio.trigger[
N
].clear()
was
called, this function returns a value immediately. After waiting for a trigger with this function, the event
detector is automatically reset and ready to detect the next trigger. This is true regardless of the
number of events detected.
Example
triggered = digio.trigger[4].wait(3)
print(triggered)
Waits up to three seconds for a trigger to be
detected on trigger line 4, then outputs the
results.
Output if no trigger is detected:
false
Output if a trigger is detected:
true
Also see
(on page 7-54)
digio.writebit()
This function sets a digital I/O line high or low.
Type
TSP-Link accessible
Affected by
Where saved
Default value
Function
Yes
Usage
digio.writebit(
N
,
data
)
N
Digital I/O trigger line (1 to 14)
data
The value to write to the bit:
•
0 (low)
•
Non-zero (high)