Signal Processor Frame Servicing
Signal Processor Frame Servicing
The following section covers maintenance of the Signal Processor frame in the
areas listed below.
■
Signal Processor Frame Module Precautions
■
Removing Modules From the Frame
■
Servicing Frame Power Supplies
■
Frame Air Filter Cleaning
Signal Processor Frame Module Precautions
WARNING
When Signal Processor Frame power is turned off, current switcher state
data will be lost. When power is restored, the switcher will reset to either a
user-defined default state, or a GVG factory default state (setup in the Define
Defaults Menu). If you wish to save the current switcher state, “learn” the
state to an empty E-MEM register. When the switcher is turned back on, you
can recall that E-MEM register to return to the previous state.
WARNING
High current capability is present in the Signal Processor Frame. Remove all
rings and other jewelry when working on extended circuit modules, and use
caution when using metal tools in the vicinity of power buses.
CAUTION
Many of the circuit modules in the Signal Processor Frame are sensitive to static
discharge. Failure to use proper static-control procedures while working on circuit
modules may cause data loss and/or electrical destruction of static-sensitive
devices.
Summary of Contents for Grass Valley 4000
Page 3: ...iii Tektronix Grass Valley Products P O Box 1114 Grass Valley CA 95945 916 478 3800 ...
Page 4: ...iv Tektronix Grass Valley Products P O Box 1114 Grass Valley CA 95945 916 478 3800 ...
Page 34: ...1 20 Section 1 System Overview ...
Page 138: ...2 104 Section 2 Installation ...
Page 196: ...3 58 Section 3 Functional Description ...
Page 286: ...Index 6 Index ...