G10 Installation Guide 7.13.2
136
C
Rev. 005-140228
LPC and FPC AMCs (IIC100 or IIC200)
The LPC100 and FPC100 are located on the IIC100 (
Figure C.33
). The LPC200 and FPC200
AMCs are located on the IIC200.
These AMCs are NOT hot swappable and can be removed ONLY after the IIC has
powered down. The G10 does not support removing these AMCs while the IIC is
powered on.
Figure C.33 - G10 IIC100 and IIC200 AMCs
Perform the following steps to remove or replace the LPC AMCs or the FPC AMCs. The
procedure is the same for the IIC100 and the IIC200.
Step
Action
1.
Power down the IIC. Refer to
Removing or Resetting the IIC100 or IIC200
for
details.
2.
Unseat the IIC approximately 2 inches from the backplane.
3.
Pull the AMC handle out until the latching mechanism is released and remove
the AMC.
4.
Insert the replacement AMC and carefully align the edges with the rail guides in
the IIC.
5.
Apply equal and steady pressure and slide the module in until the fingers of the
module snap into the internal AMC connector.
DO NOT force the board into
the slot.
6.
Push the AMC handle to the IN position.
7.
Reinsert the IIC. Refer to
Installing the IIC100 or IIC200
for details.
LPC100 AMC
FPC100 AMC
LPC100 AMC
Handle
FPC100 AMC
Handle
IIC100
LPC200 AMC
FPC200 AMC
IIC200
FPC200 AMC
Handle
LPC200 AMC
Handle
Tektronix Communications | For Licensed Users | Unauthorized Duplication and Distribution Prohibited