ESCRIPTION

 

The  Smart  AC  Outlet  has  the  form  factor  of  a  standard  NEMA  5-15R 
Decorator  style  duplex  tamper-resistant  receptacle  but  incorporates  a 
LoRa radio with power control and monitoring circuitry which allows for 
the following remote user features: 

 

Power on-off control and status 

 

Measurement  of  consumed  energy  (kWh),  line  voltage  (Vrms), 
load  current  (Arms),  load  power  (real,  reactive,  and  apparent, 
W), line frequency (Hz), and load power factor. 

Note that only the lower receptacle is controlled and monitored, the top 
receptacle  is  always  live  when  line  power  is  connected  to  the  module 
and any connected load does not contribute to the energy monitoring. 

The Smart AC Outlet also has a momentary contact push-button switch 
located  on  the  faceplate  for  local  user  on-off  control  of  the  controlled 
receptacle as well as an LED for local status indication. 

S

PECIFICATIONS

 

Dimensions 

43 mm (1.7”) W x 46 mm (1.8”) D x 104 mm (4.1”) H 

Weight 

0.12 kg (0.26 lb) 

Operating 
Environment 

Indoor residential & commercial 
0 to 40 °C (-40 to 104 °F) 
5 - 95% non-condensing RH 

Line 

120 VAC, 60 Hz, 15 A circuit 

Load 

1800 W (15 A) Resistive 
1000 W Incandescent 
5 A Electronic ballast 
1200 VA Standard ballast 
½ HP Motor 

Wire 
Termination 

Max. 2 wires per terminal except 1 wire for Ground  
#14 AWG copper or copper clad solid conductor 
16 mm (5/8”) strip length 
Torque terminal screw to 2.3 N.m (20 lbf-in) 

Surge Prot. 

IEEE C62.41 Category A 

Air Interface 

LoRa US915 (902 - 928 MHz) Class C 

Approvals 

UL pending 
FCC Pt. 15, RSS-247, FCC Pt. 27 pending 

 

W

ARNINGS AND 

P

RECAUTIONS

 

 

TO AVOID FIRE, SHOCK, OR DEATH, ALWAYS TURN OFF POWER

 

at the circuit breaker or fuse panel before wiring the module! 

 

If  you  are  unsure  or  uncomfortable  with  installation  of  this 
module, consult an electrician. 

 

To  be  installed  in  a  standard  electrical  box  and  used  in 
accordance with appropriate electrical codes and regulations. 

 

To be installed with copper or copper clad wires only. 

 

Exercise  caution  when  powering  loads  from  the  LoRa  radio-
controlled  receptacle.  Loads  connected  to  this  receptacle  may 
be  automatically  powered  on  by  a  timer  or  by  a  remote  user. 
Such unexpected operation may present a hazardous condition 
for local personnel. 

 

This product shall not be used with medical and/or life support 
equipment. 

I

NSTALLATION 

P

ROCEDURE

 

1.

 

Locate the electrical box into which the Smart AC Outlet will be 
installed. 

2.

 

Remove power to the wiring by turning off circuit power at the 
circuit breaker or fuse panel. 

3.

 

Test  the  existing  wiring  to  ensure  that  power  has  been 
removed. 

4.

 

Inspect the electrical box, a box depth of at least 2” is required. 
The electrical box may be metal or plastic but a plastic box will 
result in the best all-around RF performance. 

5.

 

Identify  the  appropriate  wiring  diagram  for  your  installation 
situation. 

6.

 

Strip wire insulation back 5/8” (16 mm) and maintain a straight 
conductor  for  each  of  the  wires  to  be  terminated  to  the 
receptacle module. 

7.

 

Connect the wires to the module in accordance with the wiring 
diagram  by  inserting  the  bare  wire  fully  into  the  wire  hole  for 
each  of  the  Line  (Hot),  Load,  and  Ground  terminals  on  the 
receptacle module. 

8.

 

Once the module is fully wired, push the wiring and the module 
into  the  electrical  box,  secure  the  module  with  the  two 
mounting  ear  screws,  and  install  the  trim  plate  with  the  two 
trim  plate  screws.  Always  use  a  plastic  faceplate  for  best  RF 
reception. 

9.

 

Reapply  power  to  the  circuit.  The  module  faceplate  LED  will 
now  begin  to  flash  indicating  connection  to  a  LoRa  network  is 
underway. 

10.

 

Connect  a  load  and  test  using  the  local  on-off  button  on  the 
receptacle faceplate. 

11.

 

Commission the module on the appropriate LoRa network. 

O

PERATION

 

R

EMOTE 

O

PERATION

 

The top receptacle is always on and does not contribute to load energy 
metering. Only the bottom receptacle is on-off controllable through the 
LoRa  radio  network.  By  default,  the  bottom  receptacle  will  be  off  after 
AC power to the module is restored, although this logic can be changed 
through the LoRa remote interface. 

Measurement  of  energy  supplied  by  the  bottom  receptacle  as  well  as 
other  real-time  parametric  information  including  line  voltage,  load 
current, load power (real, reactive, and apparent), and load power factor 
is available through the LoRa radio network. 

Please  refer  to  the  TEKTELIC  Communications  AC  Sensors  Technical 
Reference  Manual  (TRM)  for  details  regarding  the  LoRa  network 
interface. 

L

OCAL 

O

PERATION

 

The  bottom,  controlled  receptacle  can  be  toggled  on-off  by  pressing 
momentarily  the  faceplate  control  button.  By  default,  this  load  status 
change will be reported over the LoRa network. 

The  module  faceplate  has  an  LED  indicator  which  can  be  interpreted 
according to the following default logic: 

Note that this logic may be changed through the LoRa remote interface. 

Solid Blue 

Load power is OFF 
Module is connected to LoRaWAN 

Dark 

Load power if ON 
Module is connected to LoRaWAN 

90% On - 10% Off 
1s cadence 

Load power is OFF 
Module is connecting to LoRaWAN 

10% On - 90% Off 
1s cadence 

Load power if ON 
Module is connecting to LoRaWAN 

LoRa Radio Controlled 
Receptacle 

 Always-on Receptacle 

 Control Button 

 LED Indicator 