teko Astra-531 AC User Instruction Download Page 1

 

 

Astra-531 Ver.AC

 

Acoustic Surface Glass Break  

Detector

 

 

 

User Instruction

 

Sales: 
Controlex GmbH 
 

Philosophenweg 31-33 
47051 Duisburg,Germany 
+49 (0) 203/393 91 188 

[email protected]

 

www.controlex.eu

  

Warranty service and 
technical support: 
TEKO-TD 

Prospekt Pobedy str. 19 
420138 Kazan, Russia 
+7(843) 261-55-75 

[email protected]

  

www.teko.biz

  

 

Made in Russia 

     

       

Rev. 531-akv1_0_instr_EN

 

1  FUNCTION 

The  detector  is  designed  to  detect  destruction 
of  glasses,  glazed  structures  of  enclosed  area 
and  generate  an  alarm  notification  by  opening 
of signaling relay contacts

 

 

2  DETECTION ZONE 

 

 

 

3  SPECIFICATIONS 

 

Maximal detection range, m ............................ 6 
Operating frequencies: 
first, Hz .............................................. 

6000±100 

second, Hz ............................................. 

150±10 

Power supply voltage, V .................. from 8 to 15  
Current consumption, mA, max ......................18  
Overall dimensions, mm ..................... 

62×37×29 

Operating Conditions 

Temperature range, 

°

С ............from - 20 to + 50  

Relative air humidity, %  ......... up to 95  at + 35 

°

С 

                                    

Without moisture condensation 

 

4  DELIVERY SET 

Delivery  set  contains  holders  and  fasteners 
(dowel 

– 2 pcs., screw – 2 pcs.). 

 

5  OPERATING MODE 

 

Operating mode 

Plug 

name 

Jumper 

position 

High sensitivity

 of  

AC-channel 
 

Normal sensitivity

 

of  
AC-channel  

GB 

 

 

 

“Alarm  memory” 
ON

  

 

“Alarm memory” 
OFF

 

Mem 

 

 

 

AC-channel test 

Mem 

See par. 9 

6  INSTALLATION LOCATION 

 

1) 

   

Recommended installation height is at least 

2m  and  at  a  distance  not  more  than  6m  from 
the most distant spot of protected glass

.

 

2) 

Installation

 

on  ceiling,  on  a  wall,  in  window 

openings  and  between  window  frames  is 

al-

lowed

 

3) 

The  detector  cannot  be  used  in  premises 

with high level of acoustic interference. 

4) 

Alarm  loop  and  power  supply  wires  should 

be located far from power cables.

 

 
 
 
 
 
 
 
 
 
 
 

 
 
 

Reviews: