teko Astra-3731 User Manual Download Page 1

 

Astra-3731 

Wireless temperature detector  

 

 

 

User guide 

 

Manufacturer: 
TEKO-TD 

Prospekt Pobedy str. 19 
420138 Kazan, Russia 
+7(843) 528-03-69 

[email protected] 
www.teko.biz

 

 

 
Made in Russia 

 

rev. 3731-v1_4_instr_en 

1  FUNCTION 

  The  detector  is  designed  to  measure  the 

temperature at the installation site and transmit  
by radio to the Security Hub. 

  Temperature  control  is  carried  out  using  a 

built-in temperature sensor and / or a DS 18B20 
temperature sensor (not included in the delivery 
set)  connected  to  the  detector  terminal  block. 
Maximum cable length - 3 m 

ATTENTION!  The  terminal  block  must  not  be 
used to connect other sensors! 

  The range of temperatures measured by the 

detector is: 
a) built-in sensor 

–  from - 30 to + 55 °С; 

b)  external  temperature  sensor  DS  18

В20  –  

from - 55 to + 

125 °С. 

  If an external temperature  sensor is connect-

ed,  the  measurement  results  are  transmitted 
alternately from each sensor. 
The sending frequency is 12 sec. or 60 sec, set 
by a jumper (see the table in p. 4). 

  The  detector  operates  only  in  radio  mode  2, 

the jumper on the 

R

mod

 plug must be installed. 

2  SPECIFICATIONS 

 

Wireless coverage range, m ......................... 100 
Operating frequencies, MHz: 
- frequency 1 ........................................... 433.42 
- frequency 3 ........................................... 434.42 

Power supply voltage, V

 .............. from 2.6 to 3.6 

Overall dimensions, mm

 ............... 109 

× 34 × 27 

Operating Conditions 

Temperature range, 

°

С

 ............from - 30 to + 55  

Relative air humidity, %

 ....... up to 95  at + 40 

°

С 

                                   

without moisture condensation

 

3  DELIVERY SET 

The  detector  delivery  set  includes  fastening  parts 
(screws - 2 pcs., dowels - 2 pcs.), jumpers - 4 pcs. 

(installed), battery (Lithium, 3.6V, AA) - 1 pc., user 
guide - 1 pc. 

 

4  OPERATING MODES 

Setting  the  operating  mode  of  the  detector 
is  possible  within  no  more  than  10  minutes 
after installing the battery! 

ATTENTION! 

The  jumper  must  be  installed  on 

the R

mod 

 plug!  

Operating mode 

Plug 

Jumper 

Radio mode 2 (com-
patible with Security 
hub) 

R

mod

 

 

 

Frequency of 
sending 
measured 
temperature 

12 sec 

R

tst

 

 

  

 

  

 

 

    

60 sec 

Frequency 1 (compat-
ible with Security Hub) 

 

Frequency 3 

Lit 

 

 

 

 

 

External temperature 
detector connected 

 

External temperature 
detector is not used 

Ext 

  

 

 

 

 

 

 
 
 
 
 
 
 
 
 