teko Astra-361 Operating Manual Download Page 1

 

 

 

Astra-361 Version RF 

 

Wireless Water Leak Detector 

 

Operating Manual 

 

          

 

 

Rev. 361rk-v1_0_en 

The present operation manual is intended for studying

 

operat-

ing principle, correct usage, storage and maintenance of wire-
less water leak detector Astra-361ver. RF (hereinafter referred 

to as “

detector

”) (Fig. 1). 

 

The manufacturer reserves the right to make alteration regarding 
refinement  of  the  product  without  prior  notification.  All  changes 
will be imported into new edition of the operation manual. 

 

1  Function 

 

1.1 

  The  detector is  designed  for  detection 

of water leak events (except for distilled wa-
ter),  forming  an 

“Alarm”  notification  and 

sending  it  to  receiver  Astra-RVA  (hereinaf-
ter 

“RVA”) of wireless intrusion and fire de-

tection and alarming system Observer I. 

1.2 

The  detector  supports  three  operating 

frequencies. 

1.3 

 The detector is powered by a battery of 

CR2450  type  (voltage 

–  3.0 V)  or  batteries 

of comparable characteristics and design. 

 

2  Specifications 

 

Technical Parameters of Radio channel 

Operating frequency, MHz ................................................ 433.42 
Wireless coverage range, m*, min ......................................... 300 
Emission power, mWt, max ..................................................... 10 

 

General Technical Parameters 

Current consumption, mA, max: 
- transmitter OFF  ............................................................... 0.015 
- transmitter ON  ...................................................................... 25  
Power supply voltage, V ..................................... from 2.25 to 3.0 
Overall dimensions, mm, max ................................. 64 

 46 

 22 

Weight, kg, max  ................................................................... 0.05 
Average battery service life, years, min  .................................... 2 

 

Operating Conditions 

Temperature range, 

°

С ......................................... from +5 to +50  

Relative air humidity, %  .................................. up to 93 at + 40 

°

С  

no moisture condensation 

__________________________________ 

* Along the line-of-sight. Wireless coverage range is largely dependent 
on the design features of construction, the installation location, the in-
terference situation.

 

 

3  Delivery Set 

 

Wireless water leak detector Astra-361ver. RF ................. 1 pcs. 
Battery ............................................................................... 1 pcs. 
Operating manual .......................................................... ..1 copy.

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

4  Structure 

 

 

 

Fig. 2   

 

Structurally,  the  detector  is  designed  as  a  unit  consisting  of  a 
base and a removable cover (Fig. 2). The cover is attached to 
the base with screws. 
The unit houses a printed circuit board with radio elements.  
An  indicator  mounted  on  the  circuit  board  provides  for  detector 
operability supervision. 
Contact pads are located on the detector body. 
 

Information Capacity 

 

Table 1 

– Notifications processed by indicator and RVA 

 

Notification 

type 

Indicator 

RVA 

Starting detec-
tor to standby 
mode 

Lights 

once 

for 

0.5 s

  

after power up 

Norm  
 

Not lit 

Alarm 

Lights 

once 

for 

0.2  s

  when  ex-

ternal contact are closed  (short-
ed) by water 

Low supply  
voltage  

Blinks

 3 times 

every 

25 s 

when 

the  battery  charge  drops  below 
2.5

-

0.1

 V 

"+" 

–  the  notification  is  given,      "–  "  –  the  notification  is  not 

given 

 

Note

 

– 

When 

“Low  supply  voltage”  notification  appears,  re-

place the battery within a week. 

  

Pre-starting Procedure 

 

6.1 

  After  transportation  in  conditions  differing  from  those  of 

operation  keep  detector  unpacked  under  supposed  operation 
conditions for at least 4 hours.  

 

WARNING! 

Check  compliance  of  operating  frequen-

cies of detector and receiver

 

6.2 

  Registering the detector in the receiver memory 

 

Detector is registered at the moment of powering up.   

 

 

Step-1 

Unscrew the screws and 
remove the detector cover 

 

Fig. 1 

 

Indicator 

Cover removed 

  Base 

Printed 
circuit board 

 
Battery 

Contact  
pads 