BD-1/07-002
26
17.2. Setting Date
For VPC016, VPC104, VPC108, VPC116 and VPC132 keypads;
For VPC301 keypad;
18. KEYPAD INNER SETTINGS
*
These settings can not be done in VPC104 keypad.
Keypad keeps these settings in its memory so configure these settings on which
keypads settings you want to change.
18.1. Chime
Chime is activated when zone is opened or when zone is closed:
Operation
VPC108
VPC016-116
VPC132
VPC301
Open Chime
99 01
99 01
(1-8 zone)
99 02
(9-16 zone)
99 01
(1-8 zone)
99 02
(9-16 zone)
99 03
(17-24 zone)
99 04
(25-32 zone)
Keypad setting/Customize/Chime on 1-8
Keypad setting/Customize/Chime on 9-16
Keypad setting/Customize/Chime on 17-24
Keypad setting/Customize/Chime on 25-32
Close Chime
99 02
99 03
(1-8 zone)
99 04
(9-16 zone)
99 05
(1-8 zone)
99 06
(9-16 zone)
99 07
(17-24 zone)
99 08
(25-32 zone)
Keypad Setting/Customize/Chime off 1-8
Keypad Setting/Customize/Chime off 9-16
Keypad Setting/Customize/Chime off 17-24
Keypad Setting/Customize/Chime off 25-32
For VPC016, VPC104, VPC108, VPC116 and VPC132 keypads;
Enter to the master program.
[Enter]
(Program) key long until you hear a long beep.
[Enter] Your 4 digit master code.
[Enter] Address by looking table above.
[Enter] Zone number you want to active chime feature.
[Enter]
(Ok) key.
Enter to the master program.
[Enter] (Program) key long until you hear a long beep.
[Enter] Your 4 digit master code.
[Enter] Address 01 02.
[Enter] Date as shown above table.
[Enter] (Ok) key.
Enter to the master program.
[Enter] (Program) key long until you hear a long beep.
[Enter] Your 4 digit master code.
[Enter] Basic Settings/Clock Setting/Date.
[Enter] Date as shown above table.
[Enter] (Ok) key.
Summary of Contents for VAP Series
Page 1: ...VAP Series Alarm System User s Manual Issue Date 13 02 2007 TD 1 07 002 ...
Page 33: ...BD 1 07 002 32 ...
Page 34: ...BD 1 07 002 33 ...