BD-1/07-002
17
Command
Status
Confirmation
Arm/Disarm Status.
* 0 #
Armed
2 short beep
Disarmed
1 long beep
PGM1 Status
* 1 #
PGM1 On
2 short beep
PGM1 Off
1 long beep
PGM2
(There is no this PGM in VAP2xx, VAP3xx)
* 2 #
PGM2 On
2 short beep
PGM2 Off
1 long beep
PGM3
(There is no this PGM in VAP2xx, VAP3xx, VAP404)
* 3 #
PGM3 On
2 short beep
PGM3 Off
1 long beep
Note:
If there is a PGM relay output module is connected to your system, you need
to enter PGM number (up to 8) after you enter "*" on the phone.
10.2. If the panel calls the user
During alarm, your system calls the stored phone numbers in your system orderly. If
called user does not answer the phone or does not enter correct code, the same user
is called for 3 times. Then, other user phones in the system memory are called
orderly until the correct code is entered. When user answers the phone, user hears a
signal tone or message (if there is a message module in the system). Your installer
may limit the phone number which will be called
(1)
If installer configures system, user can answer phone by only pressing “*”.
11. SETTING USER PHONE NUMBERS
Master user can set user phone numbers as follows.
For VPC016, VPC104, VPC108, VPC116 and VPC132 keypads;
For VPC301 keypad;
[Press] “*” button on the phone
[Enter] Your 4 digit user code.
1
(If valid code is entered, panel sends short melody)
Enter to the master program.
[Enter] (Program) key long until you hear a long beep.
[Enter] Your 4 digit master code.
[Enter] One of following address that you want to set.
[Enter] phone number*
[Enter] (Ok) key.
Enter to the master program.
[Enter] (Program) key long until you hear a long beep.
[Enter] Your 4 digit master code.
[Enter] Basic Settings/Private Phone Numbers by using arrow keys.
[Enter] Phone number*
[Enter] (Ok) key.