BD-1/07-002
12
6.1.4. Automatic Arming/Disarming for determined time period
For example, let’s set the system as it will be armed every Tuesday at 19:00 and
disarmed at 09:00
For VPC016, VPC104, VPC108, VPC116 and VPC132 keypads;
*
In VAP2xx, VAP3xx alarm panels, enter “1” because there is only a partition.
For VPC301 keypad;
*
In VAP2xx, VAP3xx alarm panels, enter “1” because there is only a partition.
6.2. Automatic Arming on No Movement
If there is no movement on a specific zone for a determined time*, the system will be
armed automatically. This feature can be programmed only by installer. Please
contact your installer for this feature.
*
This time can be set by your installer
7. BYPASSING
Sometimes, it may be necessary to make some zones "out of service" if there is an
error on related zone/zones. For example, if a defected detector prevents to arm the
system or causes false alarm, related zone/zones must be made "out of service".
This operation is called as bypass.
Enter to the master program.
[Enter]
(Program) key long until you hear a long beep.
Your 4 digit master code.
Enter address 12 01* and enter
to arm all partitions. (Total 4
partitions)
Enter address 12 02 and enter
to arm the system on Tuesday (The 2
nd
day of the
week is Tuesday)
Enter address 12 03 and enter
to arm the system at 19:00
Enter address 12 04* and enter
to disarm all partitions. (Total 4
partitions)
Enter address 12 05 and enter
to disarm the system on Tuesday (Tuesday is 2
nd
day of the week)
Enter address 12 06 and enter
to disarm the system at 09:00
Enter
(Exit) key long until you hear a long beep.
Enter to the master program.
[Enter]
(Program) key long until you hear a long beep.
Your 4 digit master code.
Enter menu “Panel Settings/Auto Arm/Disarm/Auto Arm” and
[Enter]
(*) to arm all partitions.
(A=1, B=2, C=3, D=4)
[Enter]
to arm the system on Tuesday.
(The 2
nd
day of the week is Tuesday)
[Enter]
to arm at 19:00
Enter “Panel Settings/Auto Arm/Disarm/Auto Disarm” and
[Enter]
(*) to disarm all partitions.
(A=1, B=2, C=3, D=4)
[Enter]
to disarm the system on Tuesday.
(The 2
nd
day of the week is Tuesday)
[Enter]
to disarm the system at 09:00