C
L E A R
P
A T H
- S C
U
S E R
M
A N U A L
R
E V
.
1 . 3 6
1 1 0
T
EKNIC
,
I
NC
. T
EL
.
(585)
784-7454
A
PPENDIX
G:
W
IRING THE
I
NPUTS
Each ClearPath-SC motor has two available inputs (Input A and B). Inputs
are wired to the SC Hub and passed to the motor via the ClearPath I/O
connector as shown below.
W
IRING A
M
ECHANICAL
S
WITCH TO AN
I
NPUT
SC-Hub Internal
Mechanical
Switch
24V
GRN LED
Input B +
Input B -
Input A +
Input A -
Input B
(MiniFit-4)
ClearPath I/O
(MiniFit-8)
Data lines
(To ClearPath-SC)
Inputs A and B
(To ClearPath-SC)
Courtesy 24VDC
(Ext. supply required)
24V Return
A mechanical switch wired to Input B on the SC Hub
W
IRING A
24V
NPN
S
ENSOR TO AN
I
NPUT
SC-Hub Internal
Sensor
Main
Circuit
24V NPN Sensor
24V
GRN LED
Input B +
Input B -
Input A +
Input A -
Input B
(MiniFit-4)
ClearPath I/O
(MiniFit-8)
Data lines
(to ClearPath-SC)
Inputs A and B
(to ClearPath-SC)
Courtesy 24VDC
(Ext. supply required)
24V Return
An 24V sensor wired to one input on the SC Hub board