Caution

Improper installation and operation of this control could result in damage to equipment and possibly even personal injury.  It
is your responsibility to ensure that this control is safely installed according to all applicable codes and standards.

Step One

Getting ready

Check the contents of this package.  If any of the contents listed are missing or damaged, please refer to the Limited Warranty and
Product Return Procedure on the back of this brochure and contact your wholesaler or tekmar sales agent for assistance.

Type 252 includes:

•  One Control 252  •  One Outdoor Sensor 070  •  One Universal Sensor 071
•  One Data Brochure D 252  •  One Data Brochure D 001  •  One Application Brochure A 252

Other information available:

•  Essay E 001  •  Essay E 002

Read Application Brochure A 252 and select the correct Application for your job.

Note:

Carefully read the details of the Application, and the Sequence of Operation sections in all applicable brochures to ensure that you have
chosen the proper control, and you understand its functions within the operational requirements of your system.

DHW Operation

DHW mode using DHW Sensor 071

• A DHW Sensor 071 must be installed in terminals 

DHW Sen — Com Sen (16 and 17).

• The DHW Sensor causes the control to monitor the DHW tank temperature.  The control generates a DHW demand when 5

minutes has elapsed from the last DHW operation and the tank temperature is dropping quickly, or over a longer period of time
when the tank temperature becomes cooler than the DHW dial setting.  This DHW demand causes the control to maintain the
supply water temperature at the DHW dial s 20

°

F(11

°

C), and over time will increase the supply temperature to the DHW

dial s 40

°

F(22

°

C).

4

Heating Operation (cont.) — Outdoor temperature cold enough to require heating

With boiler minimum setting higher than heating curve requirement

The "Minimum" light will come on and the control will switch on the boiler(s).  The boiler(s) will
fire until the supply temperature reaches the minimum setting plus the differential setting.  When
this point is reached, the "Minimum" light will stay on and the control will cycle the boiler(s) to
maintain the supply water above the Minimum setting.

Outdoor temperature cold enough for heating curve operation

The "Stage" light(s) will come on and the control will fire the boiler(s).  The boiler(s) will fire until
the supply temperature reaches the heating curve desired temperature plus one half the dif-
ferential setting, where the "Stage" light(s) will turn off and the boiler(s) will be shut off.

Note:  Whenever the boiler(s) are turned off, the control will keep them off until at least the
minimum time delay has expired

 (1 minute to 5 minutes depending on degree of error).

DHW mode using external DHW Aquastat (no DHW Sensor)

• A 24Vac DHW Demand signal must be applied to terminals 

DHW Dem — DHW Dem (3 and 4).

• The DHW Demand signal causes the control to maintain a supply water temperature at the DHW dial  setting,

and over time can increase the supply temperature to the DHW dial s 20

°

F(11

°

C) .

DHW operation when control is not in heating mode

When there is a DHW demand, the "DHW Demand" light will come on and the control will operate the DHW
pump or System pump and DHW valve to generate DHW.  The boiler(s) will be cycled to maintain the
temperature required by the DHW dial setting (above). When DHW demand is removed, the boiler(s) are
turned off but the pump continues to run for 1 minute to purge the remaining heat from the boiler(s).

DHW operation when control is in heating mode

When a DHW demand occurs, the "DHW Demand" light will come on and the control will operate the DHW
pump or System pump and DHW valve to generate DHW. The control will compare the heating curve desired
supply temperature against the DHW desired supply temperature and operate the boiler(s) to maintain the
supply at whichever is the hotter desired temperature.

DHW during unoccupied  

 selector switch #4 = On

When in Unoccupied mode, the control will operate (as above), to generate DHW.

No DHW during unoccupied  

 selector switch #4 = Off

DHW will not be generated in Unoccupied mode, even with a DHW Demand signal.

1

2

3

4

Dem Dem

Dem Dem

Heat

DHW

1

2

3

4

5

6

7

8

Auto

Stage

1   2

Perm. Heat Demand

External Heat Demand

Indoor sensor

Zone control

DHW during unoccupied

DHW priority

Rotate

Off

DHW valve

DHW pump

Installation

15

2K 

RTU

19

20

10K 

Sen

Com 

Sen

21

22

Sup 

Sen

Out 

Sen

18

UnO 

Sen

16

DHW 

Sen

17

Com 

Sen

Power

Heat
Demand

DHW
Demand

WWSD

Stage 1

Stage 2

UnOcc.

Minimum

DHW
pump

System
pump

Power

Heat
Demand

DHW
Demand

WWSD

Stage 1

Stage 2

UnOcc.

Minimum

DHW
pump

System
pump

Power

Heat
Demand

DHW
Demand

WWSD

Stage 1

Stage 2

UnOcc.

Minimum

DHW
pump

System
pump

Power

Heat
Demand

DHW
Demand

WWSD

Stage 1

Stage 2

UnOcc.

Minimum

DHW
pump

System
pump

Power

Heat
Demand

DHW
Demand

WWSD

Stage 1

Stage 2

UnOcc.

Minimum

DHW
pump

System
pump

Power

Heat
Demand

DHW
Demand

WWSD

Stage 1

Stage 2

UnOcc.

Minimum

DHW
pump

System
pump

Summary of Contents for DHW Control 252

Page 1: ...n order to satisfy the DHW requirements D 252 Operating Mode selector switches Terminal Plugs Power and out put connections Terminal Plug Sensor and timer inputs Outdoor Reset Strategy pg 2 Testing pg...

Page 2: ...lected is too low the heating system will not supply hot enough water to keep the room temperature warm during colder weather If the Heating Curve selected is too high the supply water will be too hot...

Page 3: ...emperature supply temperature and indoor temperature optional Whenever 3 days pass with the control in uninterrupted WWSD the system pump will be cycled on for 20 seconds to help prevent it from seizi...

Page 4: ...mperature reaches the heating curve desired temperature plus one half thedif ferential setting where the Stage light s will turn off and the boiler s will be shut off Note Whenever the boiler s are tu...

Page 5: ...nnections The installer should test to confirm that no voltage is present at any of the wires Install the control into the base sliding it down until it snaps into place All electrical connections are...

Page 6: ...2K RTU Com Sen 20 Sup Sen 21 Out Sen Com Sen 22 Stage DHW DHW Sensor optional 071 DHW Sen DHW 10K Indoor Sensor 074 or Zone Control optional 10A 10A 10A DHW Demand When DHW requested and there is no D...

Page 7: ...and ensure that it is powered up and the voltage is correct Check the devices in the circuit limits flow switches etc for faults If the boiler operates properly when the circuit is powered up disconn...

Page 8: ...ls Com Sen UnO Sw 17 and 18 are shorted out the control switches from operating at the Occupied dial setting to operating at the Unoccupied dial setting When a tekmar Zone Control or 2K RTU RoomTemper...

Page 9: ...C above the desired temperature Delays of 8 seconds to 3 minutes for staging off depend on the degree of control error Within the differential range no boilers are staged on or off Trial setting 22 F...

Page 10: ...mp will remain on After the 5 minutes the control will automatically exit the test routine and enters the normal operating mode If there is no DHW Demand the control will not allow a pause and will pr...

Page 11: ...door Sensor or RTU input becomes shorted out the Occupied and Unoccupied dial settings will become active After any repair has been completed press the Test button to allow the control to cycle throug...

Page 12: ...bour to remove transport or reinstall a defective product tekmar will not be liable for any damage other than repair or replacement of the defective part or parts and such repair or replacement shall...

Reviews: