Installation Instructions
Drill the fixing points:
• Offer the installation panel up to the
mounting surface and mark the five
fixing points through the holes in the
backplate. Drill the five marked fixing
holes and insert the supplied wall plugs.
Offer the installation panel up to the
wall, and insert the five fixing screws
through the panel into the wall plugs.
• Drill a further fixing hole 615mm down
from the top centre of the installation
panel and insert the supplied wall plug.
Wire the unit:
• Remove the terminal cover mounting
screw and remove the cover itself.
• Wire the unit accordingly.
• Replace the terminal cover once
complete.
Fix the unit in place:
• Firstly, remove the drain tank and air
filter.
• Engage the panel hooks of the
installation panel on the back of the
unit.
• Check that the power cable is not
trapped behind the unit.
• Gently press the unit onto the wall, and
then fix it in place using the mounting
screw at the bottom.
• Replace the drain tank and air filter.
Recommended Mounting Heights
Measurements are from the bottom of the
installation panel to the floor
• Mens / Ladies: 850mm
• Disabled: 730mm