7.4. Emptying the dust collecting tank
The dust collection container must be cleaned after a certain number of operating hours. This range
depends on the amount of dust. The dust collecting tank may only be filled up to a maximum of 25%.
The filling level has to be proofed at least once a week.
CAUTION
Whirling up dust is possible due to the polluted filter cartridges!
The filter cartridges must be cleaned before emptying the dust collecting tank.This is done
by carrying out 3 manual cleanings via the unit control (see separate operating
instructions).The filter unit must be switched off beforehand but without disconnecting the
unit from the power supply.After the cleaning, disconnect the filter unit from the power supply
and secure it against being switched on again.After cleaning the filter cartridges wait about 5
minutes before opening the service door.
Before emptying the dust collecting tank hold ready an appropriate container (e.g. PE bag). The
bags are optionally available at TEKA, see list of spare parts. We recommend having PE bags in
stock.
●
Open the service door of the dust collecting housing (see chapter 2.1).
●
Open the toggle levers (B) of the dust collecting tank (A).
Risk of contusion when opening the toggle levers.
●
Carefully pull the dust collecting tank out of the housing.
●
Remove the slip-on frame (C) from the dust collecting tank.
●
Close the dust collection bag (e.g. with a cable fastener).
●
Remove the dust collection bag and store or dispose of it according to the regulations.
●
Place a new dust collection bag in the dust collection container so that the bag is put over the
edge of the dust collection container. Therefore place the slip-on frame back on the dust
collecting tank.
●
Push the dust collecting tank back into the dust collecting housing.
●
Close the toggle levers so that the dust collection container is pressed tightly against the above
chute.
●
Close the service door.
BA_Airtech_P10_IFA_190319_EN
17
19.03.2019