1.
SAFETY AND RESPONSIBILITY
- Follow the instructions in this manual when installing, operating, and maintaining
the MixRite pump and take additional safety measures appropriate to the liquid
being pumped and the temperature of the water.
- During any action, the operator must stay in front of the MixRite and wear
protective eyewear, clothing and gloves and use proper tools. DO NOT USE
METALLIC TOOLS.
- It is the responsibility of the owner/operator to make sure water flow and
pressure do not exceed the MixRite specifications.
- An air inlet, impurity or chemical damage to a seal can interrupt the dosing
function. It is recommended to periodically check that the solution is being
correctly drawn up into the MixRite.
- Be extremely careful in the presence of hazardous substances (e.g. corrosives,
toxins, solvents, acids, caustic, flammables, etc.).
- Before applying any aggressive chemicals, please consult your distributor to
confirm compatibility with the dosing pump.
- The user must respect the recommendations given by the manufacturer of the
chemical product.
- Change the suction tube as soon as it seems damaged by the chemical.
- It is advised to relieve the pressure after use.
2.
TECHNICAL DATA
2.1. MixRite Operational Conditions
Minimum Flow Rate
10 L/H (2.64 Gal/H)*
Maximum Flow Rate
2,500 L/H (660 Gal/H)
Minimum Temperature
4°C (39°F)
Maximum Temperature
40°C (104°F)
Operation Pressure Range
0.2 Bar to 8 Bar (2.9 to 120 PSI)
*7 L/H (1.85 Gal/H) in P0 model only.
Summary of Contents for MixRite 2.5
Page 7: ...3 CONFIGURATION 01 0 1 0 9 04 0 4 4 05 0 5 5 22 0 2 Fix 28 0 8 Fix...
Page 9: ...4 1 2 Mounting on Stand Stand delivered upon request...
Page 11: ...4 2 1 Installing the MixRite on a Direct Line in line...
Page 12: ...4 2 2 Installing the MixRite on a Bypass Line offline...
Page 19: ...8 SPECIFICATIONS 7...