SAFETY AND RESPONSIBILITY 

 
-  Follow the instructions in this manual when installing, operating, and maintaining 

the MixRite pump and take additional safety measures appropriate to the liquid 
being pumped and the temperature of the water. 

-  During  any  action,  the  operator  must  stay  in  front  of  the  MixRite  and  wear 

protective  eyewear,  clothing  and  gloves  and  use  proper  tools.  DO  NOT  USE 
METALLIC TOOLS. 

-  It  is  the  responsibility  of  the  owner/operator  to  make  sure  water  flow  and 

pressure do not exceed the MixRite specifications. 

-  An  air  inlet,  impurity  or  chemical  damage  to  a  seal  can  interrupt  the  dosing 

function.  It  is  recommended  to  periodically  check  that  the  solution  is  being 
correctly drawn up into the MixRite. 

-  Be extremely careful in the presence of hazardous substances (e.g. corrosives, 

toxins, solvents, acids, caustic, flammables, etc.). 

-  Before  applying  any  aggressive  chemicals,  please  consult  your  distributor  to 

confirm compatibility with the dosing pump. 

-  The user must respect the recommendations given by the manufacturer of the 

chemical product. 

-  Change the suction tube as soon as it seems damaged by the chemical. 
-  It is advised to relieve the pressure after use. 
 

2. 

TECHNICAL DATA 

 

2.1.  MixRite Operational Conditions 

Minimum Flow Rate 

10 L/H (2.64 Gal/H)* 

Maximum Flow Rate 

2,500 L/H (660 Gal/H) 

Minimum Temperature 

4°C (39°F) 

Maximum Temperature 

40°C (104°F) 

Operation Pressure Range 

0.2 Bar to 8 Bar (2.9 to 120 PSI) 

*7 L/H (1.85 Gal/H) in P0 model only. 

 

 

Summary of Contents for MixRite 2.5

Page 1: ...Propotional Pump Nahsholim 30815 Israel Tel 972 4 6395554 Fax 972 4 639 0813 www tefentech com E mail info tefentech com User Manual...

Page 2: ...cy and easy operation We wish you an excellent user experience with our product Please read this manual carefully before using the product and follow the safety guidelines For support please contact o...

Page 3: ...e additive injection directly into the water or fluid line with various flow rates feed ratios and pressure ranges These pumps are extremely durable manufactured from engineered composite materials to...

Page 4: ...9 4 2 MixRite Installation 10 4 2 1 Installing the MixRite on a Direct Line in line 11 4 2 2 Installing the MixRite on a Bypass Line offline 12 5 Operation 13 5 1 Adjusting the MixRite 13 5 2 Air Rel...

Page 5: ...ended to periodically check that the solution is being correctly drawn up into the MixRite Be extremely careful in the presence of hazardous substances e g corrosives toxins solvents acids caustic fla...

Page 6: ...L Height Air Release On Off Max 496 19 5 528 20 7 Min 457 17 9 497 19 5 160 6 3 L A A A A L 160 6 3 219 8 62 260 102...

Page 7: ...3 CONFIGURATION 01 0 1 0 9 04 0 4 4 05 0 5 5 22 0 2 Fix 28 0 8 Fix...

Page 8: ...ositioned above the liquid additive container Do not install the MixRite above an acid container fumes may damage the MixRite and protect it from possible contact with corrosive products The MixRite m...

Page 9: ...4 1 2 Mounting on Stand Stand delivered upon request...

Page 10: ...g pump in installations in which there is a risk of siphoning The strainer must be suspended at least 10 cm 4 above the bottom of the additive tank to avoid sucking up the insoluble particles that may...

Page 11: ...4 2 1 Installing the MixRite on a Direct Line in line...

Page 12: ...4 2 2 Installing the MixRite on a Bypass Line offline...

Page 13: ...obtain the desired result Adjustment must be made when there is no pressure in the MixRite Turn off the water supply and allow the pressure to drop to zero Do not remove the lower U Latch For maintena...

Page 14: ...t On pumps with On Off knob there is no air release valve It is highly recommended to use the On Off knob when the additive container is empty or if there is a need for the water flow to continue with...

Page 15: ...If there is a fear of frost and the temperature falling below 4 C 39 F empty the water from the pump To do this close the entry and exit valves securely Open and dismantle record nut that connects the...

Page 16: ...2 Wash the external surface of the unit with clean water 6 2 Cleaning and Refitting the Suction Check Valve Before removing Suction Check Valve turn off the water supply and allow the pressure to drop...

Page 17: ...tion pump test at low pressure Disconnect the water outlet hose from the outlet by installing a bypass make sure there is no water returning to the pump If the pump is working check the P as described...

Page 18: ...rn valve MixRite makes scratching noises Check if there is liquid in the additive container Add liquid to the container Check if the suction pipe is immersed and not folded Straighten or change the pi...

Page 19: ...8 SPECIFICATIONS 7...

Page 20: ...e and or defective installation or environmental accidents or corrosion by foreign bodies and liquids found within or in proximity to the MixRite The seals and O rings are not covered under warranty n...

Reviews: