tefen MixRite 2.5 User Manual Download Page 17

 

  

 

 

7. 

TROUBLESHOOTING 

 

Subject 

Check 

Solution 

The pump does not 
work. 

Direction of arrows on the pump is 
the same as water flow. 

Install the pump so that the 
arrows point in direction of 
water flow. 

Inlet and outlet valves are open. 

Open the valve 

Inlet filter is not clogged.  

Clean the filter. 

Line’s water pressure. 

Make sure there is water 
pressure in the line 

– check 

the system input filter and 
make sure it is clean. 

Springs are not broken. 

Change the motor. 

Cylinder is not scratched. 

Change cylinder. 

Piston seals are not damaged. 

Change the seals. 

Bypass installation* pump test at 
low pressure. 

Disconnect the water outlet 
hose from the outlet, by 
installing a bypass make 
sure there is no water 
returning to the pump. If 
the pump is working check 
the 

ΔP – as described in 

the item below. 

Bypass installation* make sure 
the pressure difference. 

The water pressure at the 
outlet of the pump is equal 
to or greater than the water 
pressure at the main line. 

The pump has 
stopped working. 

There is no water flow at the 
appropriate pressure. Open the 
main valve. Open the nut locking 
the motor cover, remove the 
motor cover, and remove the 
mechanism. Check if the motor 
seals are defective. 

Replace the motor seals. 

Check if the springs are broken. 

Replace the motor. 

Check if one of the parts of the 
mechanism is broken. 

Replace the motor. 

 

 

Summary of Contents for MixRite 2.5

Page 1: ...Propotional Pump Nahsholim 30815 Israel Tel 972 4 6395554 Fax 972 4 639 0813 www tefentech com E mail info tefentech com User Manual...

Page 2: ...cy and easy operation We wish you an excellent user experience with our product Please read this manual carefully before using the product and follow the safety guidelines For support please contact o...

Page 3: ...e additive injection directly into the water or fluid line with various flow rates feed ratios and pressure ranges These pumps are extremely durable manufactured from engineered composite materials to...

Page 4: ...9 4 2 MixRite Installation 10 4 2 1 Installing the MixRite on a Direct Line in line 11 4 2 2 Installing the MixRite on a Bypass Line offline 12 5 Operation 13 5 1 Adjusting the MixRite 13 5 2 Air Rel...

Page 5: ...ended to periodically check that the solution is being correctly drawn up into the MixRite Be extremely careful in the presence of hazardous substances e g corrosives toxins solvents acids caustic fla...

Page 6: ...L Height Air Release On Off Max 496 19 5 528 20 7 Min 457 17 9 497 19 5 160 6 3 L A A A A L 160 6 3 219 8 62 260 102...

Page 7: ...3 CONFIGURATION 01 0 1 0 9 04 0 4 4 05 0 5 5 22 0 2 Fix 28 0 8 Fix...

Page 8: ...ositioned above the liquid additive container Do not install the MixRite above an acid container fumes may damage the MixRite and protect it from possible contact with corrosive products The MixRite m...

Page 9: ...4 1 2 Mounting on Stand Stand delivered upon request...

Page 10: ...g pump in installations in which there is a risk of siphoning The strainer must be suspended at least 10 cm 4 above the bottom of the additive tank to avoid sucking up the insoluble particles that may...

Page 11: ...4 2 1 Installing the MixRite on a Direct Line in line...

Page 12: ...4 2 2 Installing the MixRite on a Bypass Line offline...

Page 13: ...obtain the desired result Adjustment must be made when there is no pressure in the MixRite Turn off the water supply and allow the pressure to drop to zero Do not remove the lower U Latch For maintena...

Page 14: ...t On pumps with On Off knob there is no air release valve It is highly recommended to use the On Off knob when the additive container is empty or if there is a need for the water flow to continue with...

Page 15: ...If there is a fear of frost and the temperature falling below 4 C 39 F empty the water from the pump To do this close the entry and exit valves securely Open and dismantle record nut that connects the...

Page 16: ...2 Wash the external surface of the unit with clean water 6 2 Cleaning and Refitting the Suction Check Valve Before removing Suction Check Valve turn off the water supply and allow the pressure to drop...

Page 17: ...tion pump test at low pressure Disconnect the water outlet hose from the outlet by installing a bypass make sure there is no water returning to the pump If the pump is working check the P as described...

Page 18: ...rn valve MixRite makes scratching noises Check if there is liquid in the additive container Add liquid to the container Check if the suction pipe is immersed and not folded Straighten or change the pi...

Page 19: ...8 SPECIFICATIONS 7...

Page 20: ...e and or defective installation or environmental accidents or corrosion by foreign bodies and liquids found within or in proximity to the MixRite The seals and O rings are not covered under warranty n...

Reviews: