Unpacking and Inspection

Handle with care. Check items received
against packing list to be sure that all
equipment has been received. Inspect
for shipping damage. If found, file
claim with carrier immediately.

General Safety Information

Electrically powered sump pumps
normally give many years of trouble-
free service when correctly installed,
maintained, and used. However,
unusual circumstances (interruption of
power to the pump, dirt/debris in the
sump, flooding that exceeds the
pump’s capacity, electrical or
mechanical failure in the pump, etc.)
may prevent the pump from

functioning normally. To prevent
possible water damage due to
flooding, consult your dealer about
installing a high water alarm. See the
“Troubleshooting Chart” in this
manual for information about
common sump pump problems and
remedies. For more information, see
your dealer or call customer service.

1. Know the pump application,

limitations, and potential hazards.

2. Disconnect power before servicing.

3. Release all pressure within system

before servicing any component.

4. Drain all water from system before

servicing.

5. Secure discharge line before

starting pump. An unsecured
discharge line will whip, possibly
causing personal injury and/or
property damage.

6. Check hoses for weak or worn

condition before each use, making
certain that all connections are
secure.

7. Periodically inspect system

components. Keep free of debris
and foreign objects. Perform
routine maintenance as required. 

8. Provide means of pressure relief for

pumps whose discharge line can be
shut-off or obstructed.

9. Personal Safety:

a. Wear safety glasses at all times

when working with pumps.

b. Keep work area clean,

uncluttered and properly
lighted – replace all unused
tools and equipment.

c. Keep visitors at a safe distance

from work area.

d. Make workshop child-proof –

with padlocks, master switches,
and by removing starter keys.

10. When wiring an electrically driven

pump, follow all electrical and
safety codes that apply.

1/3

9.8

7”

2”

15”

16”

12

1

2

32 lbs.

Specifications

Motor

Full Load

Switch Setting

Top

Bottom

HP

Amps

On

Off

Height

Diameter

Diameter

Wt.

48.0

40.0

29.0

15.0

24’

Performance Chart

Gallon Per Minute of Water @ Total Head In Feet

5’

10’

15’

20’

Shut Off

Description

Teel Sink Pump System, Model Number 4RK74A, is ideal for home wastewater
removal from beautician or utility sinks and wet bars, and for drain water transfer
from air conditioners or dehumidifiers. 1/3 HP submersible pump unit is equipped
with a 3-prong grounding-type power cord. Motor is oil-filled (dielectric oil) and
sealed for cooler running. Upper sleeve/lower ballbearing on motor shaft never
needs lubrication. Automatic reset thermal protection.

Specifications

Power supply required ...............................................................................115V, 60 Hz.
Liquid Temp. Range ....................................................................................32° to 130°F
Circuit Requirement (minimum) ......................................................................15 Amps
Discharge ............................................................................................................1

1

2

" NPT