background image

F

R

A
N

Ç

A

I

S

E
S
P

A
Ñ
O

L

®

Teel  Submersible Effluent and
Sewage/Solids Handling Pumps

Operating Instructions & Parts Manual   

4RK45, 4RK46, 4RK47, 4RK48, 4RK49, 4RK62 and 4RK63

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.

Form 5S4184

®

E

N
G

L

I

S

H

Printed in U.S.A.
09319
0201/020/E3

Unpacking and Inspection

Handle with care. Check items received
against packing list to be sure that all
equipment has been received. Inspect
for shipping damage. If found, file
claim with carrier immediately.

General Safety Information

READ AND FOLLOW 

SAFETY INSTRUCTIONS!

This is the safety alert symbol.

When you see this symbol on your

pump or in this manual, look for one of
the following signal words and be alert
to the potential for personal injury.

Warns about

hazards  

that will cause serious personal injury,
death, or major property damage if
ignored.

Warns about
hazards that can

cause serious personal injury, death, or
major property damage if ignored.

Warns about
hazards that will or

can cause minor personal injury or
property damage if ignored.

NOTE:

Indicates special instructions

which are important but not related to
hazards.

NOTE: 

Pump 

must 

be installed in a

vertical position 

only. 

Installing pump

in any other position will void
warranty.

4RK45

Cast iron

Cast iron

Cast iron

Cast iron

20

1

2

16

7

8

20’

117 lbs.

4RK46

Cast iron

Cast iron

Cast iron

Cast iron

20

1

2

16

7

8

20

121

4RK47

Cast iron

Cast iron

Cast iron

Cast iron

20

1

2

16

7

8

20

122

4RK48

Cast iron

Cast iron

Cast iron

Cast iron

20

1

2

16

7

8

20

121

4RK49

Cast iron

Cast iron

Cast iron

Cast iron

20

1

2

16

7

8

20

122

4RK62

Cast iron

Cast iron

Cast iron

Cast iron

18

1

2

16

7

8

20

120

4RK63

Cast iron

Cast iron

Cast iron

Cast iron

18

1

2

16

7

8

20

120

Dimensions

Pump Materials

Dimensions

Cord

Models

Base

Housing

Cover

Impeller

Height

Diameter

Length

Weight

4RK45

1

230

1

8.5

15

130° F

Sewage/solids handling

3”

4RK46

1

230/460*

3

8.5/4.1

15/15

130°

Sewage/solids handling

3

4RK47

1

1

2

230

1

12.0

15

130°

Sewage/solids handling

3

4RK48

1

1

2

230/460*

3

9.0/4.7

15/15

130°

Sewage/solids handling

3

4RK49

2

230

1

13.0

20

130°

Sewage/solids handling

3

4RK62

2

230

1

11.0

15

130°

Effluent

2

4RK63

2

230/460*

3

7.5/3.8

15/15

130°

Effluent

2

Specifications

Volts

Motor

Circuit Breaker

Maximum

@

Full Load

Rating

Fluid

Discharge

Models

HP

60 Hz.

Phase

Amps

(Amps)

Temperature

Service

NPT (in.)

Description

Teel submersible effluent pumps, Model Numbers 4RK62 and 4RK63, and
sewage/solids handling pumps, Model Numbers 4RK45, 4RK46, 4RK47, 4RK48 and
4RK49 are used for sewage, effluent and wastewater removal, sump drainage,
liquid transfer systems, circulation, dewatering, and flood control. Pump motors
range from 230V single phase with automatic thermal reset to 230/460V three
phase. 60 hertz, oil filled, 1 HP, 1

1

2

HP, and 2HP models deliver from 38 to 85 feet

of head with capacities ranging from 20 to 250 GPM.

Volute and semi-open impeller are close grained cast iron. Dual shaft seal,
extended pump out vanes and seal plate barrier provide greater seal protection.
Effluent pumps have 3/4” spherical solids handling capability. Sewage/solids
handling pumps handle 2” spherical solids. Stainless steel hardware for easy
disassembly after extended use. All pumps are manually operated except Model
4RK62, which has an automatic float switch.

* These models are pre-wired at factory for 230V.

Summary of Contents for 4RK45

Page 1: ...t iron 201 2 167 8 20 122 4RK48 Cast iron Cast iron Cast iron Cast iron 201 2 167 8 20 121 4RK49 Cast iron Cast iron Cast iron Cast iron 201 2 167 8 20 122 4RK62 Cast iron Cast iron Cast iron Cast iro...

Page 2: ...wired to interrupt power to all three incoming phases Three phase pumps are intended for permanent connection only Provide strain relief at control box for power supply cord connection to box All cont...

Page 3: ...tions on Page 1 OVERLOADS SINGLE PHASE In single phase units an automatic overload protector in the motor will protect motor from burning out due to overheating overloading When motor cools down prote...

Page 4: ...mbling pump The pump motor housing contains a special lubricating oil Keep oil clean and free of water at all times NOTE Whenever motor cover is being removed for service remove oil and replace with n...

Page 5: ...et head screws NOTE It is good practice to replace O Ring each time pump is serviced 4 Turn assembly upside down and slide new rotating member of seal onto shaft Apply soap to rubber ring to aid in sl...

Page 6: ...arily conform to the illustrations or descriptions Except as provided below no warranty or affirmation of fact expressed or implied other than as stated in the LIMITED WARRANTY above is made or author...

Page 7: ...is not high enough 2 Check that fluid level is high enough to activate to activate switch or controller switch or controller 3 Plugged vent hole in discharge pipe 3 Check to be sure that the 3 16 vent...

Page 8: ...62SS U30 62SS U30 62SS U30 62SS 4 14 1 4 20 x 1 Capscrew U30 475SS U30 475SS U30 475SS U30 475SS U30 475SS 4 15 Motor through bolts U30 941 U30 941 U30 941 U30 941 U30 941 4 16 3 16 x 3 4 Impeller ke...

Page 9: ...U30 475SS U30 475SS 4 15 Motor through bolts U30 941 U30 941 4 16 Shaft seal U9 394SS U9 394SS 1 17 Retaining washer PW43 5SS PW43 5SS 1 18 Retaining ring U9 353SS U9 353SS 1 19 Lip seal U9 417 U9 41...

Reviews: