background image

INSTRUCTIONS FOR INSTALLATION, USE AND CARE OF WATER HEATERS

STANDARD MB 30, 50, 80 lit. STANDARD MB 80 H,

PRAKTIK MB 50, 80, 100, 120 lit. PRAKTIK MB 50, 80, 100, 120 lit. Inox

PRAKTIK MB PK 80,120 lit. PRAKTIK MB PK 80, 120 lit. Inox

SLIM MB 30, 50, 80 lit. SLIM MB 30, 50, 80 lit. Inox

Summary of Contents for PRAKTIK MB 100

Page 1: ...AND CARE OF WATER HEATERS STANDARD MB 30 50 80 lit STANDARD MB 80 H PRAKTIK MB 50 80 100 120 lit PRAKTIK MB 50 80 100 120 lit Inox PRAKTIK MB PK 80 120 lit PRAKTIK MB PK 80 120 lit Inox SLIM MB 30 50...

Page 2: ...2 EN CONTENTS Technical information 3 Installation 4 Connection to water supply 8 Connection to power supply 9 Use control and maintenace of electrical water heaters 10 Waste disposal 11...

Page 3: ...ers are designed to work with pressure of the water supply pipeline The appliance is not meant for persons including children of reduced psychophysical abilities unless under supervision of persons re...

Page 4: ...0 80 Weight when full of water kg 0 6 0 6 0 6 Weight when full of water kg 17 47 22 72 29 109 Corrosion protection type Enamelled Mg anode Enamelled Mg anode Enamelled Mg anode Heater power W 2000 200...

Page 5: ...6 Weight when full of water kg 29 109 Corrosion protection type Enamelled Mg anode Heater power W 2000 Voltage 230 Time of water heating from 15 C to 75 C 320 The tank is insulated with quality polyur...

Page 6: ...3 395 454 354 300 130 360 320 130 360 130 240 300 793 744 603 395 454 354 600 130 360 460 130 360 380 240 300 KLASSA MB 50 SG KLASSA MB 80 KLASSA MB 80 SG KLASSA MB 50 604 860 219 219 480 110 480 110...

Page 7: ...415 610 Left water heater MB 80 HL Right water heater MB 80 HD Horisontal water heaters could be mounted as left or right depending on the position of the thermoregulator and this models are designed...

Page 8: ...water An interlocking must not come between the safety valve and the water heater as it would disable safety valve function Fill the water heater with water before connecting it to electric power sup...

Page 9: ...ctric water heater is not delivered with a device to cut off the power from the supply permanently A separating element of all the poles from the supply should be included according to local installat...

Page 10: ...uld be removed regularly For such interventions tank must be emptied To empty the tank please proceed as follows Disconnect the water heater from power supply Close the inlet cold water valve Open the...

Page 11: ...1592 50 0700 19889 e mail office tedanbg com Premium quality...

Reviews: