Installation and maintenance manual
INFINEE chillers
TECUMSEH EUROPE S&L
2 av. Blaise Pascal, 38090 Vaulx Milieu
Tel.: +33 (0)4 74 82 24 00 - www.tecumseh.com
ENGLISH
31
Version: 2020-01
Performance: ambient temperature 32°C
Maximum power 85 Hz
Ambient temperature
32°C
Temp. Water
Input/output
Glycol
Power
in cold
Power ABS
Without pump
Power ABS.
Total
Water flow
-4°C /-8 °C
35%
21.4 kW
10.0 kW
11.1 kW
5.3 m
3
/h
1°C /-3°C
35%
25.3 kW
11.3 kW
12.4 kW
6.5 m
3
/h
7°C / 3°C
35%
30.2 kW
13.2 kW
14.3 kW
7.8 m
3
/h
11°C / 7°C
35%
33.6 kW
14.7 kW
15.8 kW
9.7 m
3
/h
19°C / 15°C
35%
40.3 kW
18.7 kW
19.8 kW
11.7 m
3
/h
Partial load 70 Hz
Ambient temperature
32°C
Temp. Water
Input/output
Glycol
Power
in cold
Power ABS
Without pump
Power ABS.
Total
Water flow
-4°C /-8 °C
35%
18.5 kW
8.0 kW
9.1 kW
4.6 m
3
/h
1°C /-3°C
35%
22.0 kW
9.0 kW
10.0 kW
5.6 m
3
/h
7°C / 3°C
35%
26.5 kW
10.3 kW
11.4 kW
6.8 m
3
/h
11°C / 7°C
35%
29.6 kW
11.3 kW
12.4 kW
8.6 m
3
/h
19°C / 15°C
35%
36.1 kW
13.9 kW
15.0 kW
10.5 m
3
/h
Partial load 50 Hz
Ambient temperature
32°C
Temp. Water
Input/output
Glycol
Power
in cold
Power ABS
Without pump
Power ABS.
Total
Water flow
-4°C /-8 °C
35%
14.1 kW
5.5 kW
6.6 kW
3.5 m
3
/h
1°C /-3°C
35%
16.9 kW
6.1 kW
7.2 kW
4.3 m
3
/h
7°C / 3°C
35%
20.5 kW
6.9 kW
7.9 kW
5.3 m
3
/h
11°C / 7°C
35%
23.2 kW
7.4 kW
8.5 kW
6.7 m
3
/h
19°C / 15°C
35%
28.9 kW
8.7 kW
9.8 kW
8.4 m
3
/h
Partial load 25 Hz
Ambient temperature
32°C
Temp. Water
Input/output
Glycol
Power
in cold
Power ABS
Without pump
Power ABS.
Total
Water flow
-4°C /-8 °C
35%
10.4 kW
3.8 kW
4.9 kW
2.6 m
3
/h
1°C /-3°C
35%
12.5 kW
4.2 kW
5.2 kW
3.2 m
3
/h
7°C / 3°C
35%
15.4 kW
4.6 kW
5.7 kW
3.9 m
3
/h
11°C / 7°C
35%
17.5 kW
4.9 kW
6.0 kW
5.1 m
3
/h
19°C / 15°C
35%
22.1 kW
5.6 kW
6.6 kW
6.4 m
3
/h