Storage
Temperature
-20~60ºC, <80% R.H.
Power Supply
Four AAA batteries
Dimension and
Weight
270(H) x 85(W) x 43(D)mm, 700g
Safety
IEC-1010-1, UL-1244/UL-3111, CE mark
Accuracy Specifications:
Range
Resolution
Accuracy
Remarks
Function- Active Power (V x A x CosØ)
3.5kW
1W
35kW
10W
350kW
100W
±(2.0%rdg+5dgt)
1200A overload
protection
Function- Apparent Power (V x A)
3.5kVAR
1VAR
35kVAR
10VAR
350kVAR
100VAR
±(2.0%rdg+5dgt)
1200A overload
protection
Function- Reactive Power (V x A x SinØ)
3.5kVAR
1VAR
35kVAR
10VAR
350kVAR
100VAR
±(2.0%rdg+5dgt)
1200A overload
protection
Function- Power Factor (CosØ)
3.5kW
1W
35kW
10W
350kW
100W
±(3.0%rdg+5dgt)
1200A overload
protection
Function- Crest Factor
up to 6:1
select range ±(3.0%rdg+2dgt)
1200A overload
protection
Function- ACA
35A
10mA
350A
100mA
±(1.0%rdg+5dgt)
1000A
1A
±(1.0%rdg+15dgt)
Surge Mode
±(3.0%rdg+5dgt)
Function- ACV
350V
100mV
600V
1V
±(1.0%rdg+5dgt)
45 - 400Hz
bandwidth