TECNOVAP Steam Box Professional User Manual Download Page 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This  manual  is  available

  in  digital  format,  by  submitting 

a  specific  request  to  the 

following address: 

[email protected]

 

 

STEAM BOX PRO 

USER MANUAL 

Wit

integ

ra

ted

 ind

ustria

l suction unit

 

 

St

andard

 

Bacchus

 

 

 

 

With 

suction unit

 

Summary of Contents for Steam Box Professional

Page 1: ...l is available in digital format by submitting a specific request to the following address Info tecnovap com STEAM BOX PRO USER MANUAL With integrated industrial suction unit Standard Bacchus With suc...

Page 2: ...STEAM BOX PROFESSIONAL Pag 2 TECNOVAP 06 19...

Page 3: ...AND FOLLOW THIS INSTRUCTION MANUAL IT IS RECOMMENDED TO KEEP THIS INSTRUCTION MANUAL TO CONSULT IT LATER OR TO GIVE IT TO THE FOLLOWING OWNERS PLEASE READ THE SAFETY INSTRUCTIONS ON THIS HANDBOOK BEFO...

Page 4: ...A COLLECTION CENTRE ELECTRICAL AND ELECTRONIC APPLIANCES BATTERIES OIL AND SIMILAR SUBSTANCES MUST NOT BE RELEASED INTO THE ENVIRONMENT PLEASE DISPOSE OF THESE USING APPROPRIATE SEPARATED WASTE COLLEC...

Page 5: ...akage current to earth exceeds 30 mA for 30 ms or a device that can check the earth circuit SAFETY VALVE This appliance is fitted with two safety valves designed to ensure the safety of the appliance...

Page 6: ...To ensure the safety of the appliance use only original spare parts supplied or approved by the manufacturer WARNING The hoses accessories and couplings are very important for the safety of the applia...

Page 7: ...fied staff Use a set of new pipes and couplings suited for use with foodstuffs do not reuse the set couplings pipes seals adapters etc for a new connection As the appliance is mobile it is not supplie...

Page 8: ...suction optional This product is equipped with a reliable stainless steel boiler able to produce a constant powerful supply of steam 24 hours a day thanks to the automatic recharge system STEAM BOX P...

Page 9: ...4 3 6 7 2 10 0 14 4 Rated Power vacuum kW 1 0 1 2 3 0 Max Rated Power kW 3 75 7 35 10 95 14 55 5 0 8 6 11 0 15 8 4 8 8 4 11 1 15 6 Rated Steam Pressure kPa bar 1000 10 Permissible Steam Pressure kPa...

Page 10: ...ed Power kW 3 75 7 35 10 95 14 55 Rated Steam Pressure kPa bar 600 6 Permissible Steam Pressure kPa bar 1200 12 Max Steam Rated Flow g min 97 194 291 388 Max Steam Rated Flow Kg h 5 9 11 6 17 5 23 0 M...

Page 11: ...steam suction brush L 530 17 Suction unit support 56 Stainless steel accessory for upholstery 18 Suction unit bin 70 July steam hose 19 Suction unit motor fastening catches 71 Steam lance 20 Hose cou...

Page 12: ...OFESSIONAL Pag 12 TECNOVAP 06 19 7 TECHNICAL DRAWINGS 6 7 8 9 10 11 10B 11B 12 13 10A 11A 4 2 1 5 3 Steam Box Professional 2 SINGLE POWER MULTI POWER STEAM BOX PROFESSIONAL Steam Box Professional AD44...

Page 13: ...9 6 7 8 9 10 11 10B 11B 12 13 20 10A 11A 4 2 1 5 19 17 18 21 3 2 SINGLE POWER MULTI POWER 24 23 22 14 STEAM BOX PROFESSIONAL CON ASPIRATORE Steam Box Professional Steam Box Professional AD4401M AD4001...

Page 14: ...10 11 10B 11B 12 13 20 22 25 10A 11A 4 2 1 5 19 17 18 21 16 15 3 2 SINGLE POWER MULTI POWER STEAM BOX PROFESSIONAL CON ASPIRATORE INTEGRATO Steam Box Professional Steam Box Professional AD4401M AD4001...

Page 15: ...kv glir cis ml erg a kv glir cis ml erg a kv glir cis ml erg a kv glir cis ml erg a kv glir cis ml erg a kv glir cis ml erg a kv glir cis ml erg a kv glir cis ml erg a 1 5 3 Steam Box Bacchus 2 SINGL...

Page 16: ...STEAM BOX PROFESSIONAL Pag 16 TECNOVAP 06 19...

Page 17: ...STEAM BOX PROFESSIONAL Pag 17 TECNOVAP 06 19 JULY 10bar ACCESSORIES ONLY FOR MODELS 10 8 kW e 14 4 kW KIT GEYSER 10 bar...

Page 18: ...ective lights for security System ON The electronic unit the steam solenoid valves the boiler recharge pump are powered Boiler ON Switches on the heating elements the detergent pump and the overheated...

Page 19: ...oiler ON The appliance automatically recognises the Bacchus accessory inserted and activates the steam selection buttons on the control pad and the heating elements If there is no water in the boiler...

Page 20: ...roximately 10 taking care to pour the detergent in first in order to obtain a better mixture Take great care of the detergent used as some that are available on the market when heated to over 100 C th...

Page 21: ...e user of the need for routine maintenance the system is programmed to signal every 20 hours of effective work steam solenoid valve on Proceed as described in section 9 1 Boiler Maintenance to drain o...

Page 22: ...For models with overheated water injection adhere to the operating mode described above activating button 33 Both the detergent and the overheated water function must be run at intervals e g 20 second...

Page 23: ...medium 3 maximum press the button 30 to deliver the steam Use the lever 30A to lock the steam delivery button 30 Button 34 allows you to add detergent to the steam and must be run at intervals of a f...

Page 24: ...is now ready for use Switch on the main switch 4 and buttons for steam production and wait approx 3 8 minutes depending on the model until the light comes on indicating that there is steam in the boil...

Page 25: ...n buttons on the control pad Wait for the indicator light to come on indicating the presence of steam in the boiler Use the relative buttons minimum steam medium steam maximum steam depending on how m...

Page 26: ...the boiler to be emptied completely Clean any dirt off the cap with running water check that the seal on the bottom of the cap is in good condition and replace if necessary contact your supplier for...

Page 27: ...ton 30 on July and Radames or 83 on Geyser located on the hand grip and then act on the button on the control panel to activate the detergent pump hold this button down until detergent flows out of th...

Page 28: ...19 9 4 Accessory Maintenance Grease the joints of the extension pipes and accessories when required OR 29 82x2 62 PG5123 OR 6 75x1 78 PG51264 OR 9 25x1 78 2 PG51004 OR 9 25x1 78 PG5142 Imp Radames Imp...

Page 29: ...of water A Check that the switch 4 is on and that the plug 23 is correctly inserted in the socket 14 B Clean the suction hose and accessory being used C Empty the suction unit bin Steam does not come...

Page 30: ...to the difference in temperature between the steam and the accessories After using for a few minutes the problem disappears If it persists clean the boiler Noise inside the generator As it cools afte...

Page 31: ...e specifiche delle direttive conforms to the specifications of directives 2014 35 UE 2014 30 UE 2011 65 UE 2006 42 UE 2014 68 UE Per il controllo della conformit alle sopraindicate direttive sono stat...

Page 32: ...STEAM BOX PROFESSIONAL Pag 32 TECNOVAP 06 19 Routine Maintenance Working Hours Generator Frequency of intervention Notes...

Page 33: ...STEAM BOX PROFESSIONAL Pag 33 TECNOVAP 06 19 Extraordinary Maintenance Working hours Generator Date of Maintenance Description of maintenance components replaced etc...

Page 34: ...STEAM BOX PROFESSIONAL Pag 34 TECNOVAP 06 19 NOTES...

Page 35: ...STEAM BOX PROFESSIONAL Pag 35 TECNOVAP 06 19...

Page 36: ...STEAM BOX PROFESSIONAL Pag 36 TECNOVAP 06 19...

Page 37: ...STEAM BOX PROFESSIONAL Pag 37 TECNOVAP 06 19 THE MANUFACTURER RESERVES THE RIGHT TO INTRODUCE TECHNICAL AND STRUCTURAL MODIFICATIONS AND IMPROVEMENTS WITHOUT NOTICE...

Reviews: