This document contains information considered proprietary and confidential to Tecnar Automation Ltd
40101-00024-00– Rev E
Revision date: 2019-03-17
Page 31 of 43
User manual
Accuraspray4.0
4.1.2.2 Installation procedure
Attach the sensor head mounting plate to your support bracket using the 4
mounting holes.
FIGURE 16 M OUNTING THE SENSOR HEAD
Connect compressed air supply and communication cable to the sensor
head. Pull the other end of the communication cable out of the spray booth.
Connect the air hoses to the booth air supply.
FIGURE 17 SENSOR HEAD INTERFACE
Air supply
Communication
cable
Supplied with the
Accuraspray 4.0
Supplied by the user
Provide access
Summary of Contents for accuraspray 4.0