Page 3 - 4
Section 3 – Emergency Procedure
AIRPLANE ALERTS
1
st
Edition - Rev. 0
2.
A
IRPLANE ALERTS
2.1.
E
LECTRIC
P
OWER
S
YSTEM
M
ALFUNCTION
Generator message alert
NOTE
Generator message alert
(ALT)
may appear on PFD for a faulty al-
ternator or when voltage is above 16V, in this case the over-voltage
sensor automatically shuts down the alternator
1.
Generator switch:
OFF
2.
Master switch:
OFF
3.
Generator switch:
ON
4.
Master switch:
ON
If the problem persists
5.
Generator switch:
OFF
6.
Non-vital electric equipment:
Shed