END CYCLE
The END CYCLE signal indicates the end of the weld cycle. The output, which is an opto-
electronic contact, closes at the end of the hold time and may last according to the following
possibilities:
1. active until the cycle-start signal is present
2. active for 40 ms, if the cycle-start signal has already been deactivated
3. active for the entire OFF TIME if programmed to other than zero
4. active until any message or signal is deleted from the display
10.3 -
LOCK
The LOCK signal indicates current activation during the weld cycle. The output, which is an
opto-electronic contact, closes at the beginning of the weld time. It may also be the pre-weld
or the rise of current, the duration of which entails all weld times and all the active current
rising and dropping times.