--------- Programming Digital  Limits ---------

on initial power-up, the controller will automatically detect any devices that are connected (limit type, safety edge etc) 

and enter Programming Mode, indicated by a constant, slow-flashing Red L.E.D. 

Note 

: Only the internal board mounted 

'+' , '-' and 'P' buttons will operate in Programming Mode. Please observe the following procedure to set the limits :-

Run the door to the Open position and press the 'P' & '+' buttons together to save the Open Limit position. 

The Red L.E.D. will flash rapidly for 1 second to indicate that the limit position is now stored. 

Run the door to the Close position and press the 'P' & '-' buttons together to save the Close Limit position. 

The Red L.E.D. will flash rapidly for 1 second to indicate that the limit position is now stored. 

The Limit Programming Mode will then end automatically and the Red L.E.D. will stop flashing. 

If the controller does not enter Programming Mode, or you wish to re-enter Programming Mode, please press the 

'P' button for at least 2s. The Red LED will flash slowly and the Programming procedure above may then be followed. 

--------- Setting Mechanical  Limits 

On initial power-up, the controller will automatically detect any devices that are connected (limit type, safety edge etc) 

and enter Programming Mode, indicated by a constant, slow-flashing Red L.E.D. 

Note 

: Only the internal board mounted 

'+' , '-' and 'P' buttons will operate in Programming Mode. Please observe the following procedure to set the limits :-

Use the '+' button to run the door to the Open position and adjust the Open Limit cam to suit. 
Use the '-' button to run the door to the Close position and adjust the Close Limit cam to suit. 

When both limits have been set, press the 'P' button for at least 2s. 

The Limit programming Mode will then end and the Red L.E.D. will stop flashing. 

Please refer 

to the Door Operator Manual for instructions on how to adjust the mechanical limit cams. 

--------- Changing Motor Direction 

If the motor travels in the wrong direction i.e. drives Open when the Close button is pressed, then the motor direction 

can be changed by removing the power and interchanging two of the incoming supply phases. 

If the operator is reverse mounted (or if normal open rotation is reversed i.e gear & pinion drive) pressing both the 

'+' & '-' buttons for 5 seconds when in limit programming mode will reverse the motor direction. 

The Red L.E.D. will flash rapidly to indicate the change of direction. The Limit Programming procedure may then be restarted. 

----------- Resetting Limits 

To reset the limits, enter Programming Mode by pressing the 'P' button for at least 2s. 

The Red LED begins to flash slowly and the Limit Programming procedure above may then be restarted. 

Note :- If both Open 

& Close 

Limits have already been set, it is possible to change only one position 

(i.e. No requirement to program both limit positions again). 

After adjusting the required Limit position(s), exit Programming by pressing the 'P' button for at least 

2s. 

--------- Resetting the Control Panel ---------

The CS310 can be reset back to factory defaults at any time. This may be required if the CS310 has been powered without the 

correct limit type connected (e.g. digital limit encoder un-plugged) causing the automatic detect to fail, 

or if the CS310 has been used on a previous installation. 

To initiate the reset, press & hold the 'P' and '-' pushbuttons as the power is turned back on. 

Keep both buttons pressed until the Green L.E.D. turns on (after approx 10s). The CS310 will then re-start. 

L.E.D. Status

L.E.D.  Tag  Status 

Error 

Comment/ Action 

1  (Green)  Power 

Off 

No Supply present 

No operating voltage supply present 

2  (Red) 

Error  1 x Flash  Error STOP 

Stop circuit interrupted - Check Manual Override & any Stop pushbuttons/Circuits 

2 x Flash  Error RS485 

System stopped; Encoder communication error. 

Acknowledge the error by pressing Stop; restart by pressing the button. 

3 x Flash  Error Travel Limit 

System stopped and no door movement possible. 

Disconnect the P .C.B. from the power supply; reprogram the travel limit positions. 

4  x Flash  Error Motor Direction  System stopped and no door movement possible; Phase rotation is incorrect 

Reverse the motor direction as per the 'Changing Motor Direction' procedure (see above). 

5 x Flash  Error Power 

System stopped. 

Acknowledge the error by pressing Stop; restart is possible by pressing the button. 

6 x Flash  Error Running Time 

System stopped. 

Acknowledge the error by pressing Stop; restart is possible by pressing the button. 

ON 

Safety Edge Fault/ 

Deadman close only possible - Check safety edge connections/ 

Not connected 

or install safety edge for impulse close 

Note:-

Once the error has been cleared, the P.C.B. must be powered Off & On again. 

CS 310 Quick Start Guide (Stock Code: 

40-4310) 

WARNING! 

Read these instructions 

FULLY 

before use.

Installation should only be carried out by a 

COMPETENT 

installer. 

� 

>< 

!!' 

il' 

ii, 

... 

'< 

--< 

"' 

� 

"' 

s· 

"

iii 

L..3 

,o 

� 

..... x 

!!' 

... 

--< 

� 

"'

s· 

....

iii 

(')  >< 

>< 

"'� 

.. 

L_ 

() 

a

m

� 

x

� 

8 � 

X

c. .. 

�L_ 

x

\

� 

--< 

;: 

<1> 

s· 

iii 

::, 

u

0

� 

I

>< 

ft 

11 

'l� 

r-

-\, 

:v·  � 

�" 

'�� 

!( 

I°' 

� 

�--

'� 

� 

-� 

.1 

i  ,� 

�\

c

-)/, 

0, 

>< 

� 

;::: 

;:? 

., 

.... 
"' 

>l:+ 

;:? 

0, 

., 

x  x 

"' 

� 

>< 

<( 

(', 

<OU 

&

0

Key 

Description 

X1 

Mains Power Supply (under plastic cover) 

X2 

Motor terminals 

X3 

Remote  Pushbutton / Command terminals 

"' 

g! 

§ 

X4 

Safety Device terminals 

X5 

Relay Output terminals (volt-free) 

X6 

External ON/OFF switch connector 

;,, 

� 

YJ 

Pushbutton connector 

xa 

LCD Display connector 

X9 

Radio Receiver connector 

� 

X10 

24/7 Weekly Timer (under plastic cover) 

X11 

RS485 Encoder (Kostal) connector 

X12 

Ext. Radio Ree./ Loop Detector connector 

X13 

Lid Mounted CS Pushbutton connector 

X14 

CSI Interface for Pushbutton / Programmer 

.!!l 

ill 

§ 

� 

X15 

Mechanical Limit Switch terminals 

X16 

MS BUS System connector 

X17 

MS BUS System connector 

-g 

X18 

Inverter Control Interface 

X19 

230Vac 1A Fused Aux Output tenminals 

X20 

Radio Safety Edge System connector 

() 

LED1 

Green Power/ Run LED 

;,; 

>< 

LED2 

Red Status / Error LED 

51 

(+) Test Open/ Programming button 

52 

(-) Test Close/ Programming button 

53 

(P) Test Stop/ Programming button 

F1 

Voltage Selector (under plastic cover) 

o;i 

PE 

Protective  Earth terminals 

><� 

<( 

i�

,,.., 

�E: 

�� 

"

I-

·.; 

Page No:- 

1 of 2 

Rev Date:- 

12/05/16 

Date:- 

12/08/14 

Reviews: