![TechWind SDK-500 User Manual Download Page 34](http://html1.mh-extra.com/html/techwind/sdk-500/sdk-500_user-manual_1070976034.webp)
User's manual for
9.
TECHNICAL DATA
Power supply voltage
22...24...38V DC; 22V...24...27V AC
Power consumption
max. 160 VA
Current value of motor control
max. 7A
Encoder input frequency
max. 40 kHz
PWM carrier frequency
7200 Hz
Control inputs
high logic level:
low logic level:
high level active
7...24V...max.35V DC
0...2V DC
Relay outputs
NO contacts, 1A 30V DC / 1A 250V AC (cos
ϕ
= 1)
Power supply output for control inputs
and external devices
15V DC ±10% / max. 100 mA, stabilized
Communication interface (option)
RS 485, 8N1 and 8N2, Modbus RTU, not separated
Baud rate
19200 bit/sec.
Display
LCD alphanumeric, 2 x 16 characters, backlit
Data memory
non-volatile memory, EEPROM type
Protection level
IP20 (if DB9 encoder connector put)
Housing
metal
Housing dimensions
240 x 140 x 53 mm
Operating temperature
0°C do +50°C
Storage temperature
-10°C do +70°C
Humidity
5% do 90% no condensation
Altitude
up to 2000 meters above sea level
Screws tightening max. torque
0,5 Nm
Max. connection leads diameter
2,5 mm
2
/power supply and motor connectors
1 mm
2
/control input/output connectors
34