![TechWind SDK-500 User Manual Download Page 26](http://html1.mh-extra.com/html/techwind/sdk-500/sdk-500_user-manual_1070976026.webp)
User's manual for
5.
MESSAGES
CAUTION!
The last characters in either of the two lines is used for diagnostic
purposes and have following meaning:
Upper line, rightmost character:
_ (underscore) -
{OPEN INP.}
input state is low
^ -
{OPEN INP.}
input state is high
Lower line, rightmost character:
_ (underscore) -
CLOSE INP.}
input state is low
^ -
{CLOSE INP.}
input state is high
5.1.
NORMAL OPERATION
Following screens are available during the normal operation:
SCREEN 1
line1:
line2:
producer name;
door state information (initialisation, open,
closed, opening, closing, retreat) or
encoder failure message;
SCREEN 2
line1:
line2:
door speed in m/s
current value in A
SCREEN 3
26
GROS Controls
Opening < >
GROS Controls
Closing > <
GROS Controls
Initialization
GROS Controls
Encoder failure
Speed: 0.35m/s
Current: 2.15A
GROS Controls
Door is open
GROS Controls
Door is closed