MasterCAN DAC connection / Connecting analog inputs
MasterCAN DAC J1939 i/o modules. Operation manual. Version 2.0
©
Technoton, 2018
26
2.5 Connecting analog input
1) MasterCAN DAC15 analog input is connected
to signal wires of analog
voltage/frequency in compliance with the designation of contacts of
IN/OUT
connector and
the colour of the wires (see table 9).
Table 9
—
Connection of MasterCAN DAC15 analog inputs (
IN/OUT
connector)
Connector
Pinout
Connector
Contact
Number
Wire
Marking
Contact
group
Wire
Color
Circuit
Designation
Signal
Parameters
4
AFin+
I1
Red
Analog/
frequency input
(table 2)
2
AFin-
Brown
2) MasterCAN DAC2113
analog inputs are connected
to signal wires of analog
voltage/frequency in compliance with the designation of contacts of
A/B/C
connectors and
the colour of the wires (see table 10).
Table 10
—
Connection of MasterCAN DAC2113 analog inputs (A/B/C connectors)
Connector
Pinout
Connector
Contact
Number
Wire
Marking
Contact
group
Wire
Color
Circuit
Designation
Signal
Parameters
A
A1
Rin1
2
White
Resistive
input
See
(table
4)
A3
Rin1
A2
Rin2
1
A4
Rin2
B
B1
Fin
9
Yellow
Frequency
input
B5
Fin
8
B2
Ain
7
Green
Analog
input
B6
Ain
6
B3
Ain
5
B7
Ain
4
B4
Iin-
3
Brown
Current
input
B8
Iin+
Pink